6
4.
Repeat steps 1 to 3 for the middle port and for the
right port of the mix inlet manifold.
5.
Place three mix bags into the mix container.
6.
Connect the bag adapter attached to the left side
of the manifold (closest to the mix outlet) to the
mix bag in the back of the mix container.
7.
Connect the bag adapter attached to the middle of
the manifold to the mix bag in the middle of the mix
container.
8.
Connect the bag adapter attached to the right side
of the manifold (farthest from the mix outlet) to the
mix bag in the front of the mix container.
When Using Bag Connection System (BCS) with One
or Two Bags (optional kit #2183987):
When connecting one or two bags, the manifold adapters
must be installed closest to the manifold outlet and the
manifold plug(s) must be placed farthest from the manifold
outlet.
1.
Connect 3/8" (9,5mm) ID
plastic food grade tubing
to a bag adapter. Secure
with hose clamps.
2.
Slide the hose clip over
the free end of the tubing.
Attach the free end of
the tubing to a manifold
adapter. Secure with a
large hose clamp.
3.
Push the manifold
adapter with spring and
valve into the left port
(nearest the manifold
outlet) of the mix inlet
manifold and secure with
retaining clip. (See
Figure 2-5).
4.
If using two mix bags,
repeat steps 1 to 3 for
the middle port.
5.
Install a manifold plug
into each empty inlet and
secure with a retaining
clip.
6.
Place the mix bag(s) into
the mix container.
7.
Connect the bag adapter
attached to the left side
of the manifold (closest
to the mix outlet) to the
mix bag in the back of
the mix container.
Figure 2-5 Bag Connection System (Optional)
Bag Adapter
Manifold
Adapter
Retaining
Clip
Mix Inlet
Manifold
Manifold
Plug
C.
MIX LOW LEVEL INDICATOR ADJUSTMENT
The sensitivity of the “Mix Low” indication that displays on
the control panel can be adjusted to operator preference.
If more advanced notice of low mix is required, loosen the
black adjustment knobs located on the sensor brackets at
the back of the machine cabinet and slide the bracket
upwards. If the “Mix Low” message appears while there is
still sufficient mix in the container, slide the bracket down-
ward. Be sure to tighten the adjustment knobs after
properly positioning the sensor.