Owner’s Manual #
20
O431 I2 Model Machines
Error Code 5 - Freezing Cylinder Sensor
The Freezing Cylinder Sensor Error (E5) indicates
a failure of the barrel sensor or if the sensor is
out of range. If the control panel displays an E5,
press the On/Off button for the cylinder to turn
if off then back on. If the error persists, contact
your Authorized Stoelting Distributor for further
assistance.
NOTE
When the machine encounters a Freezing Cylinder
Sensor Error, the machine will continue to run using
preset timers. This mode will allow the operator to
continue serving product until the machine can be
serviced.
Error Code 6 - Hopper Sensor (single hopper machines)
The Hopper Sensor Error (E6) will not occur on
the machine.
Error Code 7 - Drive Motor
If the control panel displays a Drive Motor Error
(E7), the control does not sense current coming
from the drive motor. Press the On/Off button
for the cylinder to turn if off then back on. If the
error persists, contact your Authorized Stoelting
Distributor for further assistance.
Error Code 8 - Cab Sensor
A Cab Sensor Error (E8) indicates a failure of the
cabinet sensor or if the sensor is out of range. If
the control panel displays an E8, press the On/
Off button for the cylinder to turn if off then back
on. If the error persists, contact your Authorized
Stoelting Distributor for further assistance.
Error Code 9 - High Pressure Cutout
High Pressure Cutout Errors (E9) are usually
caused by a dirty or ineffi cient condenser. If the
control panel displays an E9 on an air cooled
machine, check for proper air clearance around
the machine. If there is an E9 on a water cooled
machine check for proper fl ow from the water
supply or kinks in the hoses.
If the error persists, contact your Authorized
Stoelting Distributor for further assistance.
Error Code 10 - Auxiliary Sensor
An Auxiliary Temperature Sensor Error (E10)
occurs if the temperature sensor on the control
board fails. Press the On/Off button for the cylinder
to turn if off then back on. If the error persists,
contact your Authorized Stoelting Distributor for
further assistance.
Error Code 11 - Prime Error
The Prime Error (E11) occurs when the pump
runs for an extended period. This usually occurs
if there is a leak in the hose or if there is a
low mix condition. If the error persists, contact
your Authorized Stoelting Distributor for further
assistance.
Error Code 12 - Left Hopper Sensor
The Left Hopper Sensor Error (E12) will not occur
on the machine.
Error Code 13 - Right Hopper Sensor
The Right Hopper Sensor Error (E13) will not
occur on the machine.
Error Code 20 - Motor Reverse
The Motor Reverse Error (E20) occurs on 3 phase
machines. If there is an E20, make sure the auger
rotation is clockwise as viewed through the front
door (Refer to Section 2.4) If the error persists,
contact your Authorized Stoelting Distributor for
further assistance.
Error Code 21 - Spigot Open Time
The Spigot Open Time Error (E21) indicates a
failure of the spigot switch. If the control senses
the spigot is open continuously for 10 minutes, the
machine will go into Sleep 3 mode. If the control
panel displays an E21, press the On/Off button
for the cylinder to turn if off then back on. If the
error persists, contact your Authorized Stoelting
Distributor for further assistance.
Содержание STOELTING O431 I2
Страница 1: ...Model O431I2 OPERATORS MANUAL Manual No 513669 Rev 0 ...
Страница 2: ......
Страница 20: ...Owner s Manual 513669 14 O431 I2 Model Machines ...
Страница 24: ...Owner s Manual 513669 18 O431 I2 Model Machines ...
Страница 30: ...Owner s Manual 513669 24 O431 I2 Model Machines ...
Страница 34: ...Owner s Manual 513669 34 O431 I2 Model Machines ...