513710 REV.3
F231 OPERATOR’S MANUAL
21
Section 4: Troubleshooting
MAINTENANCE
P
A
R
T
S
TROUBLESHOO
TING
OPERA
TION
INTRODUCTION
Thoroughly clean the mix inlet
regulator and reinstall it.
Fill the hopper with new/fresh mix.
Drain 48 oz. from the barrel to
ensure the proper air-to-mix ratio
Continue normal operation.
Is there still an
alert?
Yes
No
High Torque
High Pressure Cutout
Air-Cooled Machines
High Pressure Cutout
Water-Cooled Machines
Go to the flow chart
for the alert
Contact Stoelting White Glove
Service for further assistance for
all other alerts.
Any Alert on
IntelliTec3™
Remove any foam sitting on top of
the liquid mix in the hopper
Turn both freezing cylinders off by
toggling the Freeze buttons. Press
Left then the Freeze button. Press
Right then the Freeze button.
Turn both freezing cylinders on by
toggling the Freeze buttons for
both cylinders.
Clean
If an alert appears on the machine, complete the steps on the following pages before calling Stoelting White Glove
Service. Oftentimes the issues can be resolved using new/fresh product in a clean and sanitized machine.
Содержание Stoelting F231-I3
Страница 1: ...A VOLLRATH DIVISION Model F231 I3 F231 I3 2X Operator s Manual 513710 Rev 3...
Страница 28: ......