Section 3: Maintenance
MAINTENANCE
PA
R
T
S
TROUBLESHOO
TING
OPERA
TION
INTRODUCTION
Continue normal cleaning and sanitizing procedures.
A.9
Press and hold the Pump
button until the pump hose
reset message appears on
the screen.
A.8
Tan pump hose must be replaced with
OEM part 756204 to prevent risk of failure.
NOTE
Connect a new length of tan
hose to the mix sensor using
a clamp.
A.5
Turn the pump on and feed the
other end of the tan hose into
the left side of the black cover.
Face the natural curve of the
tan hose towards the outside
of the cover to prevent the
hose from looping around
twice.
A.6
As the hose feeds through the
cover, orient the mix sensor at
an angle so the sensor wire is
not kinked or bent at a sharp
angle.
Then turn the pump off .
Connect the hose to the tee.
A.7