Vollrath STOELTING CF101 Скачать руководство пользователя страница 9

Operators Manual #513624 

CF101 Model Machines

1. 

Uncrate the machine.

2. 

Accurate leveling is necessary for correct drainage 

of machine barrel and to ensure correct overrun. 

Place a bubble level on top of the machine at each 

corner to check for level condition. If an adjustment 

is necessary, level the machine by turning the bottom 

part of each leg in or out. Then separate the machine 

base gasket and install it with the seam to the back 

and angle to the top.

3. 

Correct ventilation is required. The machine requires 

6” clearance on both sides.

4. 

Place the Main Freezer Power Off/On switch in the 

OFF position.

5. 

Connect the power cord to the proper power supply. 

Refer to the nameplate on your machine for proper 

supply. The unit must be connected to a properly 

grounded receptacle. The electrical cord furnished 

as part of the machine has a three prong grounding 

type plug. The use of an extension cord is not 

recommended. Do not use an adapter to circumvent 

the grounding requirement.

6. 

Follow the steps in Section 3 for proper cleaning 

and assembly prior to operation. 

2.1  SAFETY PRECAUTIONS

Do not attempt to operate the machine until the safety 

precautions and operating instructions in this manual are 

read completely and are thoroughly understood.
Take notice of all warning labels on the machine. The la-

bels have been put there to help maintain a safe working 

environment. The labels have been designed to withstand 

washing and cleaning. All labels must remain legible for 

the life of the machine. Labels should be checked periodi-

cally to be sure they can be recognized as warning labels.
If danger, warning or caution labels are needed, indicate 

the part number, type of label, location of label, and quantity 

required along with your address and mail to:

STOELTING

ATTENTION: Customer Service

502 Hwy. 67

Kiel, Wisconsin 53042

2.2  SHIPMENT AND TRANSIT

The machine has been assembled, operated and inspected 

at the factory. Upon arrival at the final destination, the 

entire machine must be checked for any damage which 

may have occurred during transit.
With the method of packaging used, the machine should 

arrive in excellent condition. THE CARRIER IS RESPONSIBLE  

FOR  ALL  DAMAGE  IN  TRANSIT,  WHETHER VISIBLE OR 

CONCEALED. Do not pay the freight bill until the machine 

has been checked for damage. Have the carrier  note  any  

visible  damage  on  the  freight  bill.  If concealed damage 

and/or shortage is found later, advise the carrier within 10 

days and request inspection. The customer must place 

claim for damages and/or shortages in shipment with the 

carrier. Stoelting cannot make any claims against the carrier.

2.3  MACHINE INSTALLATION

Installation of the machine involves moving the machine 

close to its permanent location, removing all crating, set-

ting in place, assembling parts, and cleaning.

CAUTION

Installation MUST be completed by a qualified 

electrician/refrigeration specialist

Incorrect installation may cause personal injury, 

severe damage to the machine and voids 

factory warranty.

Section 2 - Description and Specifications

Содержание STOELTING CF101

Страница 1: ...Model CF101 OPERATORS MANUAL Manual No 513624 Rev 4 A VOLLRATH DIVISION...

Страница 2: ......

Страница 3: ...ice and without incurring any obligation to modify or provide new parts for machines built prior to date of change DO NOT ATTEMPT to operate the machine until instructions and safety precautions in th...

Страница 4: ...ts with the correct part number or an equivalent part We strongly recommend that you do not use replacement parts of inferior quality Safety Alert Symbol This symbol Indicates danger warning or cautio...

Страница 5: ...ze Down And Operation 7 3 5 Hold Cycle 8 3 6 Production From Hold 9 3 7 Italian Ice Freeze Down And Operation 9 3 8 Removing Mix From Machine 10 3 9 Cleaning The Machine 10 3 10 Disassembly Of Machine...

Страница 6: ......

Страница 7: ...ied service per sonnel and operators in the installation operation and maintenance of the CF101 frozen custard machine NOTE Product breakdown could happen quicker if product is stored in the freezing...

Страница 8: ...09 2 cm Weight 310 lbs 140 6 kg 410 lbs 185 9 kg Electrical 1 Phase 208 240 VAC 60Hz running amps 15A connection type NEMA6 20P power cord provided Compressor 6 690 Btu hr Drive Motor 1 1 2 hp Air Flo...

Страница 9: ...washing and cleaning All labels must remain legible for the life of the machine Labels should be checked periodi cally to be sure they can be recognized as warning labels If danger warning or caution...

Страница 10: ...Operators Manual 513624 4 CF101 Model Machines...

Страница 11: ...n disconnected G Donotoperateunderunsafeoperatingconditions Neveroperatethemachineifunusualorexcessive noise or vibration occurs 3 2 OPERATING CONTROLS AND INDICATORS Before operating the machine it i...

Страница 12: ...rigeration stops F Mix Low Light Indicator TheMIXLOWmessageappearsontheLCDdisplay to alert the operator of a low mix condition The messagedisplayswhenthereisapproximatelyone gallonofmixleftinthehopper...

Страница 13: ...arm Fig 3 3 C Make sure the flow control valve is shut by turning the control knob counterclockwise to the OFF position D Place a bucket under the slide E Pour the sanitizer into the hopper NOTE A sma...

Страница 14: ...is at the desired texture Fig 3 8 The flow control knob setting is different for each type of product NOTE Adjustments take up to 1 minute before a noticeable difference is seen in the product NOTE A...

Страница 15: ...mix that comes out of the freezing cylinder in a sanitized container and treat it as rerun C When the display reads CUSTARD READY the freezing cylinder is at the correct temperature and the auger sta...

Страница 16: ...parts must comply with local health regulations After the mix has been removed from the machine the machine must be cleaned To clean the machine refer to the following steps A Place a container under...

Страница 17: ...re wash step The following procedures are a general guideline only Consult your local and state health codes for the procedures required in your location Place all loose parts in a pan or container an...

Страница 18: ...ion of the finish grain with warm soapy water and wipe dry Do not use highly abrasive materials as they mar the finish 3 14 PREVENTATIVE MAINTENANCE Use the following maintenance schedule to keep the...

Страница 19: ...etheplasticaugerbladesinaplasticbagwith a moist paper towel This will prevent the blades from becoming brittle if exposed to dry air over an extended period over 30 days D Forwater cooledmachinesthata...

Страница 20: ...Operators Manual 513624 14 CF101 Model Machines...

Страница 21: ...ccurs when the compressor runs continuously for an extended period This error could happen if the cutout value is not attained during Standby Mode or if the Ready signal does not come on in Custard Mo...

Страница 22: ...tance Error Code 8 Cab Sensor A Cab Sensor Error E8 does not occur on the CF101 machine Error Code 9 High Pressure Cutout High Pressure Cutout Errors E9 are usually caused by a dirty or inefficient co...

Страница 23: ...ion system is set too cold for the mix 2 Call Stoelting White Glove Service Custard is running too soft 1 Flow is too high 1 Decrease the flow Machine needs to run for at least a minute before you see...

Страница 24: ...Operators Manual 513624 18 CF101 Model Machines...

Страница 25: ...9 Decal Cleaning Instructions 1 324566 Decal Wired According To 1 324584 Decal Adequate Ventilation 3 2 324594 Decal Attention Heat Sensitive 1 324686 Decal Danger Automatic Start 1 324728 Decal Conta...

Страница 26: ...Italian Ice Ser 27789 Plus 336558 Door Front Ser 0 26918 336562 Door Front Ser 26919 Plus 1 624678 5 O Ring Rear Seal Black 5 Pack Ser 0 26918 625140 O Ring Front Door 1 667868 Seal Rear Auger Orange...

Страница 27: ...ription Quantity 314484 Cover Hopper 1 417010 Insert Drip Tray 1 630049 SV Rod Flow Control 1 744276 Tray Drain 18 3 8 Long 1 744287 Tray Drip Black 1 754038 Tube Flow Control Hopper 1 417010 744287 7...

Страница 28: ...Operators Manual 513624 22 CF101 Model Machines...

Отзывы: