vollara A1041B Скачать руководство пользователя страница 10

10

REMOVING THE PURIFIER PLATE & ACTIVEPURE® CELL 

INSTALLING THE PURIFIER PLATE & ACTIVEPURE® CELL 

1 . To remove the Purification 

Plate, grasp edge of plate in 
the center and gently pull out . 

NOTE:    

If the plate is difficult 
to remove, gently press 
down on the lower 
metal contact tab .

NOTE:    

Use genuine VolIara replacement parts only . Parts from anyone other than VolIara may damage your unit and void your 
warranty . 

2 . Unlock the 

ActivePure® Cell 
connector by pressing 
on the connector’s 
locking tabs .

3 . Pull the connector 

straight out to unplug .

4 . Remove 

two (2) 
thumbscrews . 

5 . Slide the 

ActivePure® 
Cell down and 
out of unit .

When installing the Purification Plate, be sure the metal tabs are making contact with the screen on each side of the plate . 

1 . Slide the ActivePure® Cell 

up and into the unit . Be 
sure the back lip of the 
ActivePure® Cell engages 
the two slotted protrusions 
at the rear of the plate 
cage, and that the angle 
brackets and studs are 
correctly aligned .

4 . Gently insert the 

Purifier Plate 
between the 
guides  
(inside the cage) 
until it stops . 

2 . Insert the two 

thumbscrews and 
tighten . Insert the 
ActivePure® Cell 
connector into the plug 
on the plate cage . 

3 . Press the 

connector firmly 
until the two tabs 
lock into place .

5 . Replace the Filter 

Assembly, inserting 
the bottom of the 
Filter Assembly first . 

6 . Replace the Back 

Cover by inserting 
the bottom in and 
snapping into 
place .

CAUTION:   

Do not look directly at the glowing lamp . Prolonged exposure, even to reflected UV light, can cause eye damage 
according to the American Conference of Governmental Industrial Hygienists (ACGIH) Standards .

WARNING:   

 

WARNING:   

 

•  Unplug the unit before performing any maintenance procedures
•  Do not operate the Vollara Air & Surface Pro+ without the Filter Assembly and Back Cover properly installed

•  Unplug the unit before performing any maintenance procedures
•  Do not operate the Vollara Air & Surface Pro+ without the Filter Assembly and Back Cover properly installed

Содержание A1041B

Страница 1: ...AIR SURFACEPRO READ MANUAL CAREFULLY FOR PROPER USE AND OPERATION PORTABLE AIR PURIFICATION SYSTEM Creating Nature s Purity Indoors 2017 SpaceTechnology Hall of Fame Inductee Nature s Healthy Ions...

Страница 2: ...erature Warranty Three 3 Year Limited Warranty GENERAL INFORMATION If you have any questions concerning this or any Vollara product contact your Vollara Independent Business Owner or Vollara Customer...

Страница 3: ...leaner To prevent a possible fire DO NOT block the air intakes or exhaust in any manner DO NOT use on soft surfaces like a bed where openings may become blocked To avoid fire or shock hazard plug the...

Страница 4: ...Multipoint and RF Ion Generation Five Speed Fan Adjustable Purifier Control A PURE only LED Display Depart Room Mode w Adjustable Digital Timer Maintenance Reminders Replaceable ActivePure Cell Remova...

Страница 5: ...at least one inch of open area to allow unrestricted airflow OPERATION PLACEMENT OF UNIT 4 To operate the DEPART ROOM feature in unoccupied areas only press the DEPART ROOM button until the desired t...

Страница 6: ...FF FAN UP FAN DOWN Adjusts the five speed fan AREA A PURE Works when unit is in A PURE Mode to set the purifier level for the indoor area The level is indicated by both a horizontal bar graph and squa...

Страница 7: ...ong press the RESET button for 3 seconds under the power off I standby state you will hear a beep sound to let you know the reminder has been cleared When the CELL indicator starts flashing in red you...

Страница 8: ...be cleaned by vacuuming replace the Filter Assembly FILTER ASSEMBLY REPLACEMENT Contact your VolIara Independent Business Owner for replacement filters See pages 8 9 for removal and installation inst...

Страница 9: ...Optional HEPA Filter Sheet is designed specifically for areas with tobacco smoke multiple pets or anywhere excessive levels of contamination are in the air Protects your air purifier from indoor conta...

Страница 10: ...the rear of the plate cage and that the angle brackets and studs are correctly aligned 4 Gently insert the Purifier Plate between the guides inside the cage until it stops 2 Insert the two thumbscrew...

Страница 11: ...unit is displaying a REPLACE PLATE message check the Purifier Plate for serviceability if it is cracked or broken the Purifier Plate will require replacement NOTE Ensure maintenance procedures requir...

Страница 12: ...d in Are you sure the outlet is active Are the Filter Assembly and Back Cover installed properly If your unit fails to operate properly after performing troubleshooting contact your independent Vollar...

Страница 13: ...roved Internet presence for Vollara products is www vollara com To confirm warranty coverage prior to purchasing a product contact Vollara at 800 989 2299 with the serial number located on the back of...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...uant of part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate rad...

Отзывы: