10
REMOVING THE PURIFIER PLATE & ACTIVEPURE® CELL
INSTALLING THE PURIFIER PLATE & ACTIVEPURE® CELL
1 . To remove the Purification
Plate, grasp edge of plate in
the center and gently pull out .
NOTE:
If the plate is difficult
to remove, gently press
down on the lower
metal contact tab .
NOTE:
Use genuine VolIara replacement parts only . Parts from anyone other than VolIara may damage your unit and void your
warranty .
2 . Unlock the
ActivePure® Cell
connector by pressing
on the connector’s
locking tabs .
3 . Pull the connector
straight out to unplug .
4 . Remove
two (2)
thumbscrews .
5 . Slide the
ActivePure®
Cell down and
out of unit .
When installing the Purification Plate, be sure the metal tabs are making contact with the screen on each side of the plate .
1 . Slide the ActivePure® Cell
up and into the unit . Be
sure the back lip of the
ActivePure® Cell engages
the two slotted protrusions
at the rear of the plate
cage, and that the angle
brackets and studs are
correctly aligned .
4 . Gently insert the
Purifier Plate
between the
guides
(inside the cage)
until it stops .
2 . Insert the two
thumbscrews and
tighten . Insert the
ActivePure® Cell
connector into the plug
on the plate cage .
3 . Press the
connector firmly
until the two tabs
lock into place .
5 . Replace the Filter
Assembly, inserting
the bottom of the
Filter Assembly first .
6 . Replace the Back
Cover by inserting
the bottom in and
snapping into
place .
CAUTION:
Do not look directly at the glowing lamp . Prolonged exposure, even to reflected UV light, can cause eye damage
according to the American Conference of Governmental Industrial Hygienists (ACGIH) Standards .
WARNING:
WARNING:
• Unplug the unit before performing any maintenance procedures
• Do not operate the Vollara Air & Surface Pro+ without the Filter Assembly and Back Cover properly installed
• Unplug the unit before performing any maintenance procedures