background image

Page 3

Processor

 Series

acoustics

TO PREVENT ELECTRIC SHOCK, DO NOT  

REMOVE  TOP  OR    BOTTOM  COVERS.   

NO  USER  SERVICEABLE  PARTS  INSIDE. 

REFER  SERVICING  TO  QUALIFIED 

SERVICE  PERSONNEL.  DISCONNECT 

POWER  CORD  BEFORE  REMOVING 

REAR  PANEL  COVER  TO  ACCESS  GAIN 

SWITCH.

Shock Hazard - Do Not Enter

Choc Hasard - N*entrent

Schocke Hazard - Test Nicht 

                              Betrete

Urto Hazard - Do  Non Entrano

WARNING

TO REDUCE THE RISK OF ELECTRIC

SHOCK, DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE!

Magnetic Field

CAUTION:

 Do not locate sensitive high-gain equipment such as preamplifiers or tape decks 

directly  above  or  below  this  unit.  Because  this  amplifier  has  a  high  power  density,  it  has  a 

strong magnetic field which can induce hum into unshielded devices that are located nearby. 

This  field  is  strongest  just  above  and  below  the  unit.  If  an  equipment  rack  is  used,  we 

recommend  locating  the  amplifier(s)  at  the  bottom  of  the  rack  and  the  preamplifier  or  other 

sensitive equipment at the top.

The  lightning  bolt  triangle  is 

used alert the user to the risk 

of electric shock

The exclamation point triangle is used 

to alert the user to important operating 

and/or maintenance instructions.

Printed on 
recycled paper.

Содержание RESONATOR

Страница 1: ...acoustics OWNER S MANUAL RESONATOR PARAMETRIC EQ ...

Страница 2: ...OWNER S MANUAL Technical and design specifications are subject to change without notice RESONATOR PARAMETRIC EQ ...

Страница 3: ...t locate sensitive high gain equipment such as preamplifiers or tape decks directly above or below this unit Because this amplifier has a high power density it has a strong magnetic field which can induce hum into unshielded devices that are located nearby This field is strongest just above and below the unit If an equipment rack is used we recommend locating the amplifier s at the bottom of the r...

Страница 4: ...nsider the following whilst using the Resonator 1 The Resonator will accommodate both 10dB and 4dB operating levels without the need for level switching 2 The XLRs are set for 4dBu the TRS jacks for 10dBV operating levels Use the appropriate connector level to interface between your equipment and the Resonator 3 Using the TRS jack input with 4dB signal levels in some set ups may over drive the Res...

Страница 5: ...ntrol the width of the selected frequency 4 Band Frequency Control To select the frequency to be adjusted 5 Channel Bypass Turns each channels EQ on or off 6 Channel Hi Pass Filter Used to select a channels 30 Hz hi pass filter 7 Mono LED Lights when the unit is in 6 band mono mode 8 Clip LED The clip LED monitors the units output and lights 3dB before clipping 1 3 4 5 2 6 7 8 ...

Страница 6: ...sleeve ground ring signal and tip signal 3 Balanced Output XLR s 4dBu Wired pin 1 ground pin 2 ve and pin 3 ve 4 Balanced Output Jacks 10dBu Wired sleeve ground ring signal and tip signal 5 Mode Selector Selects 2 channels with 3 bands of EQ or 1 channel with 6 bands of EQ 6 Power Input IEC power input connector with fuse 230 VAC 50 Hz 1 2 3 4 3 4 5 6 ...

Страница 7: ...ion for the MF section MF Frequency control This control selects the centre frequency for MF cut or boost and is adjustable from 200Hz to 8kHz HF gain control Sets the amount of cut or boost for the HF High Frequency section HF Frequency control This control selects the centre frequency for HF cut or boost and is adjustable from 500Hz to 20kHz HF Q control Varies the Q of the cut or boost region f...

Страница 8: ...z Hi Pass filter now controls the whole unit Your input signal should now go to Channel 1 s input and the output taken from Channel 2 s output Channel 2 s input is disabled CHANNEL 2 Channel 2 s operation is identical to channel one except the input BYPASS and 30 Hz hi pass filter when used in mono mode TECHNICAL SPECIFICATIONS Input Electronically balanced 4dBu XLR 10dBu 1 4 TRS jack 20K ohm impe...

Страница 9: ... detailed description of the fault and list any other equipment used in conjunction with the faulty product Send the fault description with the faulty product do not send it separately 2 Ensure safe transportation of your unit to the authorised service centre Ship it in the original factory packaging if possible 3 Do not ship the unit in any kind of rack Ignoring this warning may result in extensi...

Страница 10: ...rective repairs upon receipt of the returned product Please save the original carton and all the packing materials in case shipping is required All products being returned to the factory or service centre for repairs must be shipped prepaid If the repairs made by Void or the Void Authorised Service Centre are not satisfactory the Owner is instructed to give written notice to Void If the defect or ...

Страница 11: ...ranty is only valid in the country of purchase 2 That the product has not been abused or operated in conjunction with unsuitable or faulty apparatus 3 That the product has not been modified disassembled or tampered with by any person other than Void Acoustics technical staff 4 That the product has not suffered damage in transit Do not send goods to Void Acoustics without first obtaining a return a...

Страница 12: ...ty Registration Thank you for purchasing this Void product Please complete this warranty registration card and cut off this part and send it to the address overleaf Date of purchase Model Serial number Suppliers name and address Post code Tel Your name and address Post code Tel ...

Отзывы: