Hotplates at a point 800 mm to 850 mm above the floor and in the region outside the width of
the appliance to a distance of 250 mm.
Inlet connection region for flexible hose
After connecting to gas, check for leaks using soapy solution, never a naked flame.
Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the hotplate, for
example, the inside of the cupboard door so it is clearly visible for any service technician.
SETTING THE GAS PRESSURE:
Fit a manometer with a 6 mm rubber hose to the test point on the regulator (f or natural gas).
For the
Model
P640STX, P640STG, P750STG-1, P950STX, P950STG, P950STX-1,
P950STG-1 , light Triple Ring and Auxiliary burner on and adjust test point pressure to 1.00
kPa. Turn the two burners off and on again and recheck the pressure is same as set previously
or adjust as required.
For all the other models, light all burners on and adjust test point pressure to 1.00 kPa. Turn
burners off and on again and recheck the pressure is same as set previously or adjust as
required.
TEST FOR CORRECT OPERATION:
After installation and test point setting, each burner ignition and operation must be tested
individually and with all burners operating. This testing must be done by the installer before
leaving.
ADJUSTING THE BURNER MINIMUM FLAME HEIGHT:
NOTE: This adjustment can only be performed by authorised service personnel.
The minimum burner flame is factory adjusted for the gas type stated on the gas type label
adjacent to the gas connection and should not require adjustment. Adjustment may be
required if the hotplate has been converted from Natural gas to Universal LPG or vice versa.
GAS CONVERSION INSTRUCTIONS:
The manufacturers servicing instructions detail how authorised personnel may convert the
hotplate from Natural gas to Universal LPG or from Universal LPG to Natural gas. Contact the
manuf acturer or agent as required.
9
Gas Conversion (ULPG -NG)
If the required gas conversion kit is not supplied with your appliance, Gas Conversion
shall only be undertaken by authorized persons.
The ULPG to NG conversion kit contains
-NG Regulator
-NG Gas Type label
-Auxiliary Jet
φ
0.9mm
-Semi-Rapid Jet
φ
1.18mm
- Rapid Jet
φ
1.5mm
-Wok Jet
φ
0.70mm(IN)+
φ
1.05mm(OUT)X2
Converting to a different gas type
When Converting from ULPG to NG ensure that the ULPG test point is removed and
replaced with the AGA Approved NG Regulator supplied in this kit. The test point
pressure must be adjusted to 1.00kPa with the largest burner operating on maximum
flame.
Changing the jets
1. Remove pan supports, burner heads and cups.
2. Use a size 7 socket wrench to unscrew and remove the jets,
replacing them with those supplied in this kit. Ensure you
use the correct jet for the corresponding burner.
3. Fit the Gas type label supplied with this kit next to the gas
connection point and remove the existing label.
Setting the minimum level
1.
Remove Panels, knobs and water dish.
2.
Reassemble the burner heads, caps and knobs.
3.
Light one of the burners and turn the tap to minimum flame.
4.
Use a thin blade screwdriver to turn the by-pass screw located on the
right of the brass shaft as shown right. Turn the by-pass screw fully
counterclockwise. The result should be a small, stable flame which
is uniform around the entire burner ring. If not, turn the by-pass
screw anti-clockwise until satisfied with the flame.
5.
Check that the burner does not go out when the tap is turned
quickly from the maximum to the minimum position.
6.
Repeat for each burner.
7.
Remove the burner heads, caps and knobs.
8.
Reassemble Panels, burner heads, caps, knobs and pan supports.