Vogelzang International VG450EL Скачать руководство пользователя страница 9

VGZ-014 /  20120424.0

 

Vogelzang International Corp. 

VG450EL FrontiErsman™

 / 

Page 9

ChImNEY CONNECTIONS continued …

brickwork of a chimney. If a chimney does not 
have a liner, or it is damaged, have it relined by a 
professional. 

DO NOT USE a chimney that is 

unlined or damaged!)

 If you have any ques-

tion regarding the condition of the chimney,  
consult a qualified licensed contractor, qualified 
engineer, competent mason, certified Chimney 
Sweep, or a knowledgable inspector. Consult your 
insurance company if you cannot find a qualified 
expert.

CauTIOn: nOT all FIrePlaCe 
ChIMneYs are suITaBle FOr 
COnVersIOn TO  aCCOMMODaTe  
COnneCTIOn TO a wOOD sTOVe. 
CheCk wITh a qualIFIeD eXPerT.

Many prefabricated fireplaces are of the “zero-

clearance fireplace” category. These consist of 
multilayered metal construction. Connecting a 
stove to such a device will void the manufacturer’s 
warranty.

Venting a stove directly into a fireplace does 

not meet code and should not be attempted. (This 
constitutes connection to another appliance - the 
fireplace.) Combustion products will be deposited 
and build up in the firebox or fireplace. The stove 
warranty will be void with such an installation. Do 
not create a hazard in your home by connecting in 
this manner.

FIG. 10 - Fireplace Conversion

trimwork, ceilings and walls. Positioning the 

center of the stove pipe entry into the chimney 

24” below the ceiling should insure proper 

clearance for a 6” stovepipe.

2.  Install a fire clay (5/8˝ minimum thickness) 

thimble. Make sure the thimble is flush with 

the inner surface of the chimney liner and does 

not protrude into the flue (see figure 6).

3.  Secure the thimble with refractory mortar. The 

thimble should be surrounded by 12˝ of solid 

unit masonry brickwork or 24˝ of stone.

4.  Install the stovepipe into the thimble as far as 

possible without extending past the flue lining 

(see figures 4 & 6 on pages 5& 6). 

5.  A small airspace (about 1/2˝) should remain 

between the stovepipe and thimble to allow for 

expansion of the pipe. Seal this airspace with 

high-temperature caulking or ceramic wool.

6.  Secure and seal the damper in the closed posi-

tion using high-temp caulking, ceramic wool, 

or furnace cement. Also check to see if the 

chimney has a cleanout. If it does, make sure it 

is closed and sealed as well. A leaky cleanout 

will greatly reduce draft efficiency.
If you have any questions regarding venting 

your stove, contact the manufacturer or contact 
the National Fire Protection Association (NFPA) 
and request a copy of the latest editions of NFPA 
Standard 211 and NFPA Standard 908. Their ad-
dress is:

 Battery March Park, Quincy, MA 02269.

FIrePlaCe InsTallaTIOn

Directly connecting the stovepipe 

into the existing masonry chimney 
(figure 10 “Type A” Fireplace Con-
version) of the fireplace is the only 
approved method of installation. This 
is a complicated and involved process 
and to insure safety should only by 
done by a qualified installer.

1.  An entry hole must be cut through 

the masonry and tile liner with 

minimal damage to the liner. At 

least 8˝ of liner must remain below 

the entry position. When locat-

ing the stove and stovepipe, all 

minimum clearances must be ob-

served from combustible surfaces 

including mantels, combustible 

Continued on next page

Содержание VG450EL

Страница 1: ...6 READ ALL INSTRUCTIONS CAREFULLY BEFORE Installing OR OPERATING This STOVE Failure to follow instruc tions may result in property damage bodily injury or even death NOTE It is recommended Installation be completed by a qualified Heating Equipment Installer Do NOT install in a mobile home Refer to markings on STOVE labels for additional information Safety Notice If this stove is not properly insta...

Страница 2: ...od draft See specifics in installation instructions 9 Be sure that your chimney is safely constructed and in good repair Have the chimney inspected by the fire department or a qualified inspector Your insurance company should be able to recommend a qualified inspector Chimney connector pipe must be in good condition Replace if necessary before using stove 10 Creosote or soot may build up in the ch...

Страница 3: ... egress in the event of a fire 30 Do not install in a sleeping room 31 Do not install in an alcove or inside a fireplace 32 Install at least one smoke detector on each floor of your home Detectors should be located away from the heating appliance to avoid false alarms Detectors should be located close to sleeping areas Follow the smoke detector manufacturer s placement and installation instruction...

Страница 4: ...cts as a heat deflector This panel must be in place for safe operation 7 Attach rear deflector to the rear side corners of the stove using four screws 8 On VG450ELGB models only attach blower assembly to rear of heat deflector NOTE Make sure ceramic gasket is positioned between rear deflector and blower assembly Attach two 2 air deflectors 33 to the top of the rear heat deflector When installed th...

Страница 5: ... continued CAUTION Keep furnishings and other combustible materials away form the stove NOTE Before firing woodstove slide firebricks towards the rear so no gaps remain between bricks Fig 2 Top View Minimum Corner Clearances from Combustible Surfaces Fig 1 Top View Minimum Clearance Dimensions from Combustible Surfaces FLOOR PROTECTOR DASHED LINE SHOWS HORIZONTAL CHIMNEY CONNECTOR AND ADDITIONAL F...

Страница 6: ... no more than a maximum of 3 76mm apart 6 It is recommended that no more than two 2 90 bends be used in the stovepipe installa tion The use of more than two 90 bends may decrease the amount of draw and possibly cause smoke spillage Where possible use only corrugated nonadjustable elbows These provide a better seal 7 The connector pipe must not pass through an attic or roof space closet or any conc...

Страница 7: ... economical to rent or purchase Factors such as wind baromet ric pressure trees terrain and chimney temperature can have an adverse effect on the draft The manufacturer cannot be held responsible for ex ternal factors leading to less than optimal drafting Should you have a problem with inadequate draft you should contact a licensed heating and cooling contractor for assistance in solving the probl...

Страница 8: ...bove Be aware that not all manufactured chimney is of the UL 103 HT type NOTE It is recommended that you contact a licensed heating and cooling contractor consult your local yellow pages for chimney installation Manufactured chimney with the proper re quired UL listing is available from most home centers hardware stores and HVAC supply stores If you have access to the internet you may wish to view...

Страница 9: ...sh with the inner surface of the chimney liner and does not protrude into the flue see figure 6 3 Secure the thimble with refractory mortar The thimble should be surrounded by 12 of solid unit masonry brickwork or 24 of stone 4 Install the stovepipe into the thimble as far as possible without extending past the flue lining see figures 4 6 on pages 5 6 5 A small airspace about 1 2 should remain bet...

Страница 10: ...s sepa rated from combustibles by a minimum of 6 152mm of glass fiber insulation Opening shall be covered and thimble support ed with a sheet steel support minimum 24 gauge in thickness D Chimney Section Pass through Solid insulated listed factory built chimney length with an inside diameter 2 51mm larger than the chimney connec tor and having 1 25 4mm or more of insulation serving as a pass throu...

Страница 11: ... less buildup of tars soot or creosote will occur in the chimney 1 Always open draft damper before opening the feed door 2 When adding fuel be careful not to smother the fire Do not build fires against glass on models with glass door CAUTION HOUSE FIRE HAZARDS Do not store wood on floor pro tector underneath stovepipe or any wherewithin minimum clearances from combustible surfaces specified for th...

Страница 12: ...e lining When ignitedthis creosote makes an extremely hot fire The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred If creosote has accumulated 3mm or more it should be removedto reduce the risk of a chimney fire Failure to remove creosote may result in igni tion and may cause a house building...

Страница 13: ...not burn well Such a fire will produce excessive smoke that will cool and condense in the chimney creating creosote Excessive amounts of creosote buildup can ignite causing a chimney fire with the possibility of struc tural elements igniting as well Correct any draft related issues before using the stove The following are some possible causes of insufficient draft Please note that one or more fact...

Страница 14: ...to impact the glass 3 Do not build fires against or that might fall against the glass 4 Do not clean the glass with materials that may scratch or otherwise damage the glass Scratches on the glass can develop into cracks or breaks during operation 5 Never attempt to clean the glass while the unit is hot allow to dry thoroughly before reuse If deposits are not very heavy normal glass cleaners are ad...

Страница 15: ...e appliance is not in operation and is thoroughly cooled 2 Remove old door gasket and clean channel 3 Using an approved high temperature gasket cement apply a thin coat in bottom of channel 4 Starting at hinge side of door work gasket into channel around door unit end butt and trim to length 5 Close door and allow three to four hours for cement to set before firing appliance Blower Maintenance The...

Страница 16: ...or 1 19 Firebox Bottom 1 20 Firebox 1 21 Rear Deflector 1 22 Hardware Pack not shown 1 Models VG450ELGB only 32 Complete Blower Assembly F 4 32a Blower Housing only 1 32b Blower Motor not shown 1 32c Blower Power Cord not shown 1 32d Cord Strain Relief not shown 1 32e Ceramic Fiber Gasket not shown 1 33 Air Deflector 2 1 Flue Collar 1 2 Top Support Rails 2 3 Baffle Hangers 2 4 Baffle 1 5 Door Cast...

Страница 17: ...safety glasses Keep children away and discard broken glass safely 1 Be sure stove has cooled before beginning 2 Using a screwdriver remove three screws 27 and glass retainer 26 3 Remove two nuts 28 and air wash deflector 29 4 Remove glass 24 Replace with 8 x10 high temperature ceramic glass only 5 Re install glass reversing steps 1 3 When re placing broken glass remove gasket 25 from broken glass ...

Страница 18: ...r protector a Use formulas in step 1 above to calculate R value of proposed material s b For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the floor protector system is equal to or greater than the floor protector specifications given the alternate is acceptable Definitions Thermal conductance C BTU W hr ft2 F m2 K Thermal conductivity k Btu in...

Страница 19: ...VGZ 014 20120424 0 Vogelzang International Corp VG450EL Frontiersman Page 19 Chimney Stove Maintenance Log date of service performed by description ...

Страница 20: ...lieves in Him shall not perish but have eternal life John 3 16 MADE IN CHINA ThisVogelzang heating appliance is safe when installed properly and will provide you with years of service However always exercise good judgement when you are using this stove You are dealing with FIRE Fire is inherently dangerous and must be treated with respect Stay warm and in good health Respectfully yours SteveVogelz...

Отзывы: