tools

safety Glasses & Gloves
Pencil
6 foot Folding rule or Tape Measure
Tin snips
Drill: hand or electric
1/8” dia. Drill Bit (sheet metal screws)
screwdrivers (blade and Phillips type)
14mm nut Driver or ratchet with 14mm socket

CauTIOn: sTOVe Is heaVY. Make sure YOu 
haVe aDequaTe helP anD use PrOPer 
lIFTInG TeChnIques wheneVer MOVInG 
sTOVe.

1.  Uncrate the stove and remove cardboard 

packing, styfofoam and protective poly bag.  

Remove rear deflector (#21) from the carton. 

(Save cardboard for further assembly.)

2.  Remove parts from inside stove. Parts in-

clude: one damper collar (#1), four legs (#16), 

hardware pack (#22) and air deflectors (#33)  

located inside firebox.

3.  Place flattened carton behind stove and care-

fully turn stove over onto its back on carton.

4.  Remove the four 14mm nuts holding the  

bottom floor shield in place.

5.  Without removing the floorshield, place each 

leg in position and secure using the four (4) 

TOOls anD MaTerIals requIreD FOr InsTallaTIOn

materials

(NOTE: The following items are NOT included with your stove)

Flooring Protection: 40” x 48” as specified (see page 4)

Chimney Connection: 6” dia. minimum 24 MsG black or 26 MsG 

blue steel straig ht stove pipe or elbow(s) as required.

1/2” sheet Metal screws
Chimney: existing 6” lined masonry chimney or 6” inside dia. 

manufactured chimney system listed to ul 103 hT.

Furnace Cement (manufacturer recommends rutland Code 78 

or equivalent)

Continued on next page

14mm nuts removed in step 4. Tighten nuts 

securely.

6.  Carefully lift stove to upright position.

warnInG: MeTal Panel FasTeneD Be-
Tween leGs aCTs as a heaT DeFleCTOr.  
ThIs Panel MusT Be In PlaCe FOr saFe  
OPeraTIOn.

7.  Attach rear deflector to the rear side corners of 

the stove using four screws.

8.  On VG450ELGB models (only), attach  

blower assembly to rear of heat deflector.  

NOTE: Make sure ceramic gasket is positioned 

between rear deflector and blower assembly. 

Attach two (2) air deflectors (#33) to the top 

of the rear heat deflector. When installed, the 

angled lip should face towards the front of the 

stove.

9.  Attach damper collar to rear top surface of stove 

using machine screws.

lOCATINg STOvE

1.  The stove must be placed on solid concrete, 

solid masonry, or when installed on a com-

bustible floor, on a listed UL1618 type 2 floor 

protector, such as Hy-C or Imperial Model 

UL 4048BK or equivalent with 0.8 R-factor. 

(NOTE: to calculate R-value of alternative 

materials see page 16). The base must extend 

at least 16” beyond the side with the access 

door, 8” to the sides of fuel opening, 8” behind 

the stove, and must  extend under the stove 

pipe and 2” beyond each side if it is elbowed 

towards a wall. (See figures 1 & 3 and consult 

local building codes and fire protection ordi-

nances)

CauTIOn: (FIre hazarD) CarPeTInG anD 
OTher COMBusTIBle MaTerIal MusT nOT 
COVer The  FlOOr  PrOTeCTOr. These  
MaTerIals MusT reMaIn OuTsIDe OF  
COMBusTIBle ClearanCes, see FIG. 1– 3.

2.  The stove must have its own flue. 

DO nOT 

COnneCT ThIs unIT TO a ChIMneY 

Flue serVInG OTher aPPlIanCes.

3.  After observing the clearances to combus-

tible materials (figures 1–3), locate your floor  

protector accordingly (figure 1) and care-

fully place the stove in your selected location.   

Install connector pipe, elbows, and thimble as  

NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, for the installation or maintenance of 
your wood stove and assumes no responsibility of any incidental or consequential damages.

Содержание VG450EL

Страница 1: ...6 READ ALL INSTRUCTIONS CAREFULLY BEFORE Installing OR OPERATING This STOVE Failure to follow instruc tions may result in property damage bodily injury or even death NOTE It is recommended Installation be completed by a qualified Heating Equipment Installer Do NOT install in a mobile home Refer to markings on STOVE labels for additional information Safety Notice If this stove is not properly insta...

Страница 2: ...od draft See specifics in installation instructions 9 Be sure that your chimney is safely constructed and in good repair Have the chimney inspected by the fire department or a qualified inspector Your insurance company should be able to recommend a qualified inspector Chimney connector pipe must be in good condition Replace if necessary before using stove 10 Creosote or soot may build up in the ch...

Страница 3: ... egress in the event of a fire 30 Do not install in a sleeping room 31 Do not install in an alcove or inside a fireplace 32 Install at least one smoke detector on each floor of your home Detectors should be located away from the heating appliance to avoid false alarms Detectors should be located close to sleeping areas Follow the smoke detector manufacturer s placement and installation instruction...

Страница 4: ...cts as a heat deflector This panel must be in place for safe operation 7 Attach rear deflector to the rear side corners of the stove using four screws 8 On VG450ELGB models only attach blower assembly to rear of heat deflector NOTE Make sure ceramic gasket is positioned between rear deflector and blower assembly Attach two 2 air deflectors 33 to the top of the rear heat deflector When installed th...

Страница 5: ... continued CAUTION Keep furnishings and other combustible materials away form the stove NOTE Before firing woodstove slide firebricks towards the rear so no gaps remain between bricks Fig 2 Top View Minimum Corner Clearances from Combustible Surfaces Fig 1 Top View Minimum Clearance Dimensions from Combustible Surfaces FLOOR PROTECTOR DASHED LINE SHOWS HORIZONTAL CHIMNEY CONNECTOR AND ADDITIONAL F...

Страница 6: ... no more than a maximum of 3 76mm apart 6 It is recommended that no more than two 2 90 bends be used in the stovepipe installa tion The use of more than two 90 bends may decrease the amount of draw and possibly cause smoke spillage Where possible use only corrugated nonadjustable elbows These provide a better seal 7 The connector pipe must not pass through an attic or roof space closet or any conc...

Страница 7: ... economical to rent or purchase Factors such as wind baromet ric pressure trees terrain and chimney temperature can have an adverse effect on the draft The manufacturer cannot be held responsible for ex ternal factors leading to less than optimal drafting Should you have a problem with inadequate draft you should contact a licensed heating and cooling contractor for assistance in solving the probl...

Страница 8: ...bove Be aware that not all manufactured chimney is of the UL 103 HT type NOTE It is recommended that you contact a licensed heating and cooling contractor consult your local yellow pages for chimney installation Manufactured chimney with the proper re quired UL listing is available from most home centers hardware stores and HVAC supply stores If you have access to the internet you may wish to view...

Страница 9: ...sh with the inner surface of the chimney liner and does not protrude into the flue see figure 6 3 Secure the thimble with refractory mortar The thimble should be surrounded by 12 of solid unit masonry brickwork or 24 of stone 4 Install the stovepipe into the thimble as far as possible without extending past the flue lining see figures 4 6 on pages 5 6 5 A small airspace about 1 2 should remain bet...

Страница 10: ...s sepa rated from combustibles by a minimum of 6 152mm of glass fiber insulation Opening shall be covered and thimble support ed with a sheet steel support minimum 24 gauge in thickness D Chimney Section Pass through Solid insulated listed factory built chimney length with an inside diameter 2 51mm larger than the chimney connec tor and having 1 25 4mm or more of insulation serving as a pass throu...

Страница 11: ... less buildup of tars soot or creosote will occur in the chimney 1 Always open draft damper before opening the feed door 2 When adding fuel be careful not to smother the fire Do not build fires against glass on models with glass door CAUTION HOUSE FIRE HAZARDS Do not store wood on floor pro tector underneath stovepipe or any wherewithin minimum clearances from combustible surfaces specified for th...

Страница 12: ...e lining When ignitedthis creosote makes an extremely hot fire The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred If creosote has accumulated 3mm or more it should be removedto reduce the risk of a chimney fire Failure to remove creosote may result in igni tion and may cause a house building...

Страница 13: ...not burn well Such a fire will produce excessive smoke that will cool and condense in the chimney creating creosote Excessive amounts of creosote buildup can ignite causing a chimney fire with the possibility of struc tural elements igniting as well Correct any draft related issues before using the stove The following are some possible causes of insufficient draft Please note that one or more fact...

Страница 14: ...to impact the glass 3 Do not build fires against or that might fall against the glass 4 Do not clean the glass with materials that may scratch or otherwise damage the glass Scratches on the glass can develop into cracks or breaks during operation 5 Never attempt to clean the glass while the unit is hot allow to dry thoroughly before reuse If deposits are not very heavy normal glass cleaners are ad...

Страница 15: ...e appliance is not in operation and is thoroughly cooled 2 Remove old door gasket and clean channel 3 Using an approved high temperature gasket cement apply a thin coat in bottom of channel 4 Starting at hinge side of door work gasket into channel around door unit end butt and trim to length 5 Close door and allow three to four hours for cement to set before firing appliance Blower Maintenance The...

Страница 16: ...or 1 19 Firebox Bottom 1 20 Firebox 1 21 Rear Deflector 1 22 Hardware Pack not shown 1 Models VG450ELGB only 32 Complete Blower Assembly F 4 32a Blower Housing only 1 32b Blower Motor not shown 1 32c Blower Power Cord not shown 1 32d Cord Strain Relief not shown 1 32e Ceramic Fiber Gasket not shown 1 33 Air Deflector 2 1 Flue Collar 1 2 Top Support Rails 2 3 Baffle Hangers 2 4 Baffle 1 5 Door Cast...

Страница 17: ...safety glasses Keep children away and discard broken glass safely 1 Be sure stove has cooled before beginning 2 Using a screwdriver remove three screws 27 and glass retainer 26 3 Remove two nuts 28 and air wash deflector 29 4 Remove glass 24 Replace with 8 x10 high temperature ceramic glass only 5 Re install glass reversing steps 1 3 When re placing broken glass remove gasket 25 from broken glass ...

Страница 18: ...r protector a Use formulas in step 1 above to calculate R value of proposed material s b For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the floor protector system is equal to or greater than the floor protector specifications given the alternate is acceptable Definitions Thermal conductance C BTU W hr ft2 F m2 K Thermal conductivity k Btu in...

Страница 19: ...VGZ 014 20120424 0 Vogelzang International Corp VG450EL Frontiersman Page 19 Chimney Stove Maintenance Log date of service performed by description ...

Страница 20: ...lieves in Him shall not perish but have eternal life John 3 16 MADE IN CHINA ThisVogelzang heating appliance is safe when installed properly and will provide you with years of service However always exercise good judgement when you are using this stove You are dealing with FIRE Fire is inherently dangerous and must be treated with respect Stay warm and in good health Respectfully yours SteveVogelz...

Отзывы: