Vogelzang International VG450EL Скачать руководство пользователя страница 2

Page 2 

VG450EL FrontiErsman™ 

www.vogelzang.com

 

VGZ-014 / 20120424.0

1.  the installation of this stove must comply with your 

local building code rulings. Please observe the 
clearances to combustibles (see reference figures 
1– 3). Do not place furniture or other objects within 
the clearance area.

2.  Verify that the stove is properly assembled and 

installed before firing the stove for the first time. 
after reading these instructions, if you have any 
doubt about your ability to complete your installation  
properly, you must obtain the services of a  
professional licensed installer familiar with all  
aspects of safe and correct installation. 

 DO nOT  

use TeMPOrarY Or MakeshIFT COMPrO-
MIses  
during installation. there must be nO  
DeVIaTIOn Or alTeraTIOn OF anY kInD
 from 
the very specific instructions spelled out in this in-
struction manual as it pertains to the installation of 
this woodstove.  

nO eXCePTIOns!

3. 

DO nOT store wood, flammable liquids or other 
combustible materials too close to the unit. refer 
to certification label on back of unit and reference 
figures 7 – 9 in this manual.

4. 

DO nOT InsTall ThIs sTOVe In a MOBIle 
hOMe, ManuFaCTureD hOMe, TraIler Or 
TenT – nO eXCePTIOns! 
(HUD Federal stan-
dard: 24 CFr Ch.XX).

5. 

DO nOT eleVaTe ThIs sTOVe BY anY Means. 
(i.e. bricks under legs, cement blocks)  stove legs 
must set directly upon the solid-surface non-combus-
tible floor as specified in this stove instruction man-
ual.  

DO nOT MODIFY ThIs sTOVe In anY waY!  

stove must be installed with legs provided, attached 
as shown in the instructions. assemble only with 
original parts as supplied and shown in this manual. 
DO nOT OPeraTe a sTOVe ThaT Is MIssInG 
anY ParTs! 
if any parts are missing or defective, 
please notify the dealer or manufacturer immediately. 
replace missing, broken or worn parts with factory 
original or equivalent parts only. 

6. 

CauTIOn: DO nOT alTer COMBusTIOn aIr 
COnTrOl ranGe TO InCrease FIrInG Or 
FOr anY reasOn. 
altering or tampering with air 
control beyond normal capacity will create unsafe 
and hazardous conditions.

7.  always connect this stove to a chimney and vent to 

the outside. never vent to another room or inside 
a building. 

DO nOT COnneCT ThIs unIT TO a 

ChIMneY Flue serVInG anOTher aPPlI-
anCe.

8. 

DO nOT COnneCT a wOOD BurnInG sTOVe 
TO an aluMInuM TYPe B Gas VenT. 
this is 
not safe. Use code-approved lined masonry or a UL 
103 Ht Listed residential type and Building Heat-
ing appliance chimney. Use a 6” diameter chimney 
or larger, that is high enough to give a good draft. 
(see specifics in installation instructions).

9.  Be sure that your chimney is safely constructed and 

in good repair. Have the chimney inspected by the fire 
department or a qualified inspector. Your insurance 
company should be able to recommend a qualified 
inspector. Chimney connector pipe must be in good 
condition. replace if necessary before using stove.

10.  Creosote or soot may build up in the chimney con-

nector and chimney and cause a house/building 
fire. inspect the chimney connector and chimney 
twice monthly during the heating season and clean 
if necessary. (see service Hints, page 14)

11. 

In The eVenT OF a ChIMneY FIre, turn the 
damper control to closed position, leave the building 
and 

Call The FIre DeParTMenT IMMeDIaTe-

lY! Have a clearly understood plan on how to handle 
a chimney fire by contacting your local fire authority 
for information on proper procedures in the event of 
a chimney fire. after the fire is out, the chimney must 
be cleaned and inspected for any stress or cracks 
before starting another fire. Check the condition of 
any combustibles surrounding the chimney.

12.  to prevent injury, do not allow anyone to use this 

stove who is unfamiliar with the correct operation 
of the stove.

13.  Do not allow ashes to accumulate above top of ash 

drawer.

14. 

DIsPOsal OF ashes  ashes should be placed 
in a steel container with a tight fitting lid and moved 
outdoors immediately. the closed container of 
ashes should be placed on a noncombustible floor 
or on the ground, well away from all combustible 
materials, pending final disposal. if the ashes are 
disposed of by burial in soil or otherwise locally 
dispersed, they should be retained in the closed 
container until all cinders have completely cooled. 
other waste shall not be placed in this container. 

15. the special paints used on your stove may  

give off some smoke and an odor while  
they are curing during the first 12 to 15 fires.  addi-
tional smoke and odor may be emitted from the light 
oils used in construction of the fire box. this should 
disappear after a short period of time and not occur 
again. Persons with lung conditions or owners of sus-
ceptible domestic pets (such as birds) should take  
prudent precautions. open windows and 
doors as needed to clear smoke and/or odor. 
Paint discoloration will occur if the stove is  
over fired.

16.  this stove has a painted surface which is durable 

but it will not stand rough handling or abuse. When 
installing your stove, use care in handling. 

17. 

DO nOT eleVaTe The FIre. Build fire directly on 
the bottom of the firebox. this stove has not been 
tested with the use of grates, andirons or other means 
of elevating the fire and must not be used.

SAFETY INSTRUCTIONS

Содержание VG450EL

Страница 1: ...6 READ ALL INSTRUCTIONS CAREFULLY BEFORE Installing OR OPERATING This STOVE Failure to follow instruc tions may result in property damage bodily injury or even death NOTE It is recommended Installation be completed by a qualified Heating Equipment Installer Do NOT install in a mobile home Refer to markings on STOVE labels for additional information Safety Notice If this stove is not properly insta...

Страница 2: ...od draft See specifics in installation instructions 9 Be sure that your chimney is safely constructed and in good repair Have the chimney inspected by the fire department or a qualified inspector Your insurance company should be able to recommend a qualified inspector Chimney connector pipe must be in good condition Replace if necessary before using stove 10 Creosote or soot may build up in the ch...

Страница 3: ... egress in the event of a fire 30 Do not install in a sleeping room 31 Do not install in an alcove or inside a fireplace 32 Install at least one smoke detector on each floor of your home Detectors should be located away from the heating appliance to avoid false alarms Detectors should be located close to sleeping areas Follow the smoke detector manufacturer s placement and installation instruction...

Страница 4: ...cts as a heat deflector This panel must be in place for safe operation 7 Attach rear deflector to the rear side corners of the stove using four screws 8 On VG450ELGB models only attach blower assembly to rear of heat deflector NOTE Make sure ceramic gasket is positioned between rear deflector and blower assembly Attach two 2 air deflectors 33 to the top of the rear heat deflector When installed th...

Страница 5: ... continued CAUTION Keep furnishings and other combustible materials away form the stove NOTE Before firing woodstove slide firebricks towards the rear so no gaps remain between bricks Fig 2 Top View Minimum Corner Clearances from Combustible Surfaces Fig 1 Top View Minimum Clearance Dimensions from Combustible Surfaces FLOOR PROTECTOR DASHED LINE SHOWS HORIZONTAL CHIMNEY CONNECTOR AND ADDITIONAL F...

Страница 6: ... no more than a maximum of 3 76mm apart 6 It is recommended that no more than two 2 90 bends be used in the stovepipe installa tion The use of more than two 90 bends may decrease the amount of draw and possibly cause smoke spillage Where possible use only corrugated nonadjustable elbows These provide a better seal 7 The connector pipe must not pass through an attic or roof space closet or any conc...

Страница 7: ... economical to rent or purchase Factors such as wind baromet ric pressure trees terrain and chimney temperature can have an adverse effect on the draft The manufacturer cannot be held responsible for ex ternal factors leading to less than optimal drafting Should you have a problem with inadequate draft you should contact a licensed heating and cooling contractor for assistance in solving the probl...

Страница 8: ...bove Be aware that not all manufactured chimney is of the UL 103 HT type NOTE It is recommended that you contact a licensed heating and cooling contractor consult your local yellow pages for chimney installation Manufactured chimney with the proper re quired UL listing is available from most home centers hardware stores and HVAC supply stores If you have access to the internet you may wish to view...

Страница 9: ...sh with the inner surface of the chimney liner and does not protrude into the flue see figure 6 3 Secure the thimble with refractory mortar The thimble should be surrounded by 12 of solid unit masonry brickwork or 24 of stone 4 Install the stovepipe into the thimble as far as possible without extending past the flue lining see figures 4 6 on pages 5 6 5 A small airspace about 1 2 should remain bet...

Страница 10: ...s sepa rated from combustibles by a minimum of 6 152mm of glass fiber insulation Opening shall be covered and thimble support ed with a sheet steel support minimum 24 gauge in thickness D Chimney Section Pass through Solid insulated listed factory built chimney length with an inside diameter 2 51mm larger than the chimney connec tor and having 1 25 4mm or more of insulation serving as a pass throu...

Страница 11: ... less buildup of tars soot or creosote will occur in the chimney 1 Always open draft damper before opening the feed door 2 When adding fuel be careful not to smother the fire Do not build fires against glass on models with glass door CAUTION HOUSE FIRE HAZARDS Do not store wood on floor pro tector underneath stovepipe or any wherewithin minimum clearances from combustible surfaces specified for th...

Страница 12: ...e lining When ignitedthis creosote makes an extremely hot fire The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred If creosote has accumulated 3mm or more it should be removedto reduce the risk of a chimney fire Failure to remove creosote may result in igni tion and may cause a house building...

Страница 13: ...not burn well Such a fire will produce excessive smoke that will cool and condense in the chimney creating creosote Excessive amounts of creosote buildup can ignite causing a chimney fire with the possibility of struc tural elements igniting as well Correct any draft related issues before using the stove The following are some possible causes of insufficient draft Please note that one or more fact...

Страница 14: ...to impact the glass 3 Do not build fires against or that might fall against the glass 4 Do not clean the glass with materials that may scratch or otherwise damage the glass Scratches on the glass can develop into cracks or breaks during operation 5 Never attempt to clean the glass while the unit is hot allow to dry thoroughly before reuse If deposits are not very heavy normal glass cleaners are ad...

Страница 15: ...e appliance is not in operation and is thoroughly cooled 2 Remove old door gasket and clean channel 3 Using an approved high temperature gasket cement apply a thin coat in bottom of channel 4 Starting at hinge side of door work gasket into channel around door unit end butt and trim to length 5 Close door and allow three to four hours for cement to set before firing appliance Blower Maintenance The...

Страница 16: ...or 1 19 Firebox Bottom 1 20 Firebox 1 21 Rear Deflector 1 22 Hardware Pack not shown 1 Models VG450ELGB only 32 Complete Blower Assembly F 4 32a Blower Housing only 1 32b Blower Motor not shown 1 32c Blower Power Cord not shown 1 32d Cord Strain Relief not shown 1 32e Ceramic Fiber Gasket not shown 1 33 Air Deflector 2 1 Flue Collar 1 2 Top Support Rails 2 3 Baffle Hangers 2 4 Baffle 1 5 Door Cast...

Страница 17: ...safety glasses Keep children away and discard broken glass safely 1 Be sure stove has cooled before beginning 2 Using a screwdriver remove three screws 27 and glass retainer 26 3 Remove two nuts 28 and air wash deflector 29 4 Remove glass 24 Replace with 8 x10 high temperature ceramic glass only 5 Re install glass reversing steps 1 3 When re placing broken glass remove gasket 25 from broken glass ...

Страница 18: ...r protector a Use formulas in step 1 above to calculate R value of proposed material s b For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the floor protector system is equal to or greater than the floor protector specifications given the alternate is acceptable Definitions Thermal conductance C BTU W hr ft2 F m2 K Thermal conductivity k Btu in...

Страница 19: ...VGZ 014 20120424 0 Vogelzang International Corp VG450EL Frontiersman Page 19 Chimney Stove Maintenance Log date of service performed by description ...

Страница 20: ...lieves in Him shall not perish but have eternal life John 3 16 MADE IN CHINA ThisVogelzang heating appliance is safe when installed properly and will provide you with years of service However always exercise good judgement when you are using this stove You are dealing with FIRE Fire is inherently dangerous and must be treated with respect Stay warm and in good health Respectfully yours SteveVogelz...

Отзывы: