Start-up
32
WBV.XRP.003.EN XRC100QD SIK V6.0
Checklist before start-up
Safety
Have you taken action to ensure that the XRipper rotors are not accessible during operation?
Are the main switch and maintenance and repair switch easy to reach?
Installation
Are the wall bracket and extension rails properly installed?
Drive
Is the motor connected correctly to the power supply, if applicable (
documents provided by the
motor manufacturer)?
Star or delta connection, voltage, frequency (see name plate and inside of terminal box)?
Motor protection ensured, e.g. by a circuit breaker?
A short switching time should be set for star-delta starting, if present.
A short start ramp should be set for the soft starter, if present.
Is the soft starter, if present, dimensioned and configured correctly?
Units should be suitable for heavy starting.
Is the motor connected correctly to the hydraulic lines, if applicable (
documents provided by the
motor manufacturer)?
Buffer chamber, XRipper gearbox
Are the optional buffer chamber assemblies correctly installed? Are they correctly adjusted?
Is the buffer chamber pressure OK, if applicable?
Chap.
“Maintenance” – “Buffer chamber”.
Is the type of buffer fluid OK?*
Is the fluid level in the buffer chamber OK?*
Are the oil grade and oil level in the XRipper gearbox OK?*
*Requirements met by the XRipper when delivered
ATTENTION
Pull up the XRipper during temporary shutdowns.
To prevent solid matter from blocking up the XRipper inlet and causing problems when starting it up again,
the XRipper must be pulled up for temporary shutdown.