4.2.5 Back-to-back distance measurement
The measuring device must be correctly inserted into the track at the measuring point. Press button 4
from on the keypad. Position the measuring device so that the centre measuring probe of the broad
support makes contact on the inside (that is, on the check rail)! With the adjusting knob, turn the
measuring probe of the narrow support towards the wing rail as far as it will go (
à
Fig. 11). The
measurement value can now be read.
Fig. 11:
4.2.6 Cant measurement
The measuring device must be correctly inserted into the track at the measuring point. Press button 1
on the keypad. With the adjusting knob, turn the measuring probe of the narrow support towards the
rail head as far as it will go (
à
Fig. 12). Wait a few seconds until the inclination sensor has come to
rest, then you can read off the measurement value.
Fig. 12: