3. PRODUCT DESCRIPTION

If improperly used, the device can present risks to persons, animals and material property.

 

ʸ

Use the device according to its designated use only.

 

ʸ

Do not convert or modify the device to enhance its performance without authorisation.

 

ʸ

Only qualified personnel are permitted to perform work on the device or system.

3.1. Technical data

WARNING  

Hazards caused by improper use!

Transport and storage

-25 °C to +55°C

Relative humidity

up to 90% at 20°C

Tab. 1 Ambient conditions during operation

Type of voltage

DC

DC polarity of the electrodes

Usually positive

Shielding gas (DIN EN ISO 14175)

CO

2

 and mixed gas M21

Wire types

Commercially available round wires

Voltage rating

Peak value of 113 V

Protection type of the machine-side connectors (EN 60 529)

IP3X

Control device in torch handle

For 42 V and 0.1 to 1 A

Tab. 2 General torch data according to EN 60 974-7

Type

Type of

cooling

Load

DC

Wire Ø

Gas flow

Cooling

Flow

pressure

Single
circuit

Standard
light arc

CO

2

M21

Max. supply
temp.

Min.
flow rate

Min.

Max.

A

A

%

mm

l/min

°C

l/min

bar

bar

MT G serie
150

Air

170

170

60

0.6 - 1.0

250

Air

230

220

60

0.8 - 1.2

300

Air

280

260

60

0.8 - 1.2

350

Air

330

310

60

1.0 - 1.6

MT W serie
440

Liquid

500

450

100

0.8 - 1.6

10 - 20

50

1.5

1.5

3.5

540

Liquid

600

550

100

1.0 - 1.6

10 - 20

50

1.5

1.5

3.5

Tab. 3 Product-specific torch data (EN 60 974-7) 

MT G

 and 

MT W

English

- English -

Standard length L

3.00 m / 4.00 m

Coolant connection

Plug-in nipple, nom. diam. 5mm

Cooling unit power

Min. 800 W

Control lead

2-wire

Tab. 4 Cable assembly

Содержание Bohler Welding MT G 150

Страница 1: ...1 Firmenname oder Division www voestalpine com Lasting Connections MIG MAG WELDING TORCH voestalpine Böhler Welding www voestalpine com welding ...

Страница 2: ...3 Fig 1 Setting up MT G Fig 2 Setting up MT W Fig 3 Connecting the coolant 1 1 2 2 3 3 4 4 5 1 4 2 3 Functions ...

Страница 3: ...ons may result in risks to the life or health of personnel environmental dama ge or material damage The product may only be operated in a technically perfect condition in compliance with the operating instructions ʸ ʸ The manufacturer will accept no liability for damage caused by nonobservance of the operating instructions ʸ ʸ Use suitable means to protect yourself and bystanders from the hazards ...

Страница 4: ...ol for damage and for its perfect func tioning in accordance with its designated use Welding ʸ ʸ Arc welding may cause damage to eyes skin and hearing Please always wear the required safety clothing eye and ear protection in compliance with the relevant regulations in the country in question ʸ ʸ Any metal vapors especially lead cadmium copper and beryllium are harmful Ensure sufficient ventilation...

Страница 5: ...available round wires Voltage rating Peak value of 113 V Protection type of the machine side connectors EN 60 529 IP3X Control device in torch handle For 42 V and 0 1 to 1 A Tab 2 General torch data according to EN 60 974 7 Type Type of cooling Load DC Wire Ø Gas flow Cooling Flow pressure Single circuit Standard light arc CO2 M21 Max supply temp Min flow rate Min Max A A mm l min C l min bar bar ...

Страница 6: ...o install the wire guide with a little preload excess length is required NOTICE NOTICE NOTICE Risk of injury Puncture or cut in wounds may be caused by the wire electrode ʸ ʸ Keep your hands out of the danger zone ʸ ʸ Wear the correct protective gloves CAUTION 4 2 MT G with pluggable gas nozzle and contact tip holder Setting up MT G Fig 1 p 3 1 Pluggable gas nozzle 2 Contact tip 3 Pluggable contac...

Страница 7: ...aused by the wire electrode ʸ ʸ Keep your hands out of the danger zone ʸ ʸ Wear the correct protective gloves CAUTION 4 5 Attaching the cable assembly on the machine side 1 Join the central connector and the central socket at the wire feeder 2 Use the connection nut to secure both of these 3 Attach the coolant supply and return connectors to the MT W 4 Attach the shielding gas and control lead con...

Страница 8: ...f the gas supply ʸ ʸ Close off the coolant supply ʸ ʸ Disconnect the coolant supply and return hoses ʸ ʸ Close off the compressed air supply ʸ ʸ Disconnect all electrical connections Electric shock Dangerous voltage due to defective cables ʸ ʸ Check all live cables and connections for proper installation and damage ʸ ʸ Replace any damaged deformed or worn parts Risk of burns Risk of burns from hot...

Страница 9: ...28 voestalpine Böhler Welding www voestalpine com welding 240 2019 GL ...

Отзывы: