Linea Plus AG
SECTION 3
TECHNICAL DATA
Concentric Flue
Reduction in flue
length for each bend
Bend
45
°
90
°
0.5 m
1.0 m
Twin Flue
Reduction in flue
length for each bend
Bend
45
°
90
°
1.0 m
1.0 m
Height
Width
Depth
Weight dry
Weight full
Plus AG
820mm (32.3)
500mm (19.7)
355mm (14.0)
48kg (105.6lb)
51kg (112.2lb)
3.1
Units Dimensions and values are given in the
preferred Sl Units with Imperial units in brack-
ets where applicable.
3.2
Dimensions and Contents
Water content: 3 litres (.66 gals)
for further dimensions see figs 12 - 16
3.3
Connection sizes
Heating flow and return: Nut and olive for
22mm o.d. Cold water inlet: Nut and olive for
15mm o.d. Hot water outlet: Nut and tail for
15mm o.d. Gas Service: Nut and tail for 15mm
o.d. Safety valve outlet: 15mm comp.or cap-
illary
Flue outlet/Air inlet: nom dia 60/100mm spe-
cially supplied with boiler (concentric).
Flue outlet/Air inlet: nom dia 80/80mm spe-
cially supplied with boiler (twin).
3.4
Installation Requirements
3.4.1
Clearances (Horizontal or Vertical Flue)
Minimum - above casing 225mm (9in) Mini-
mum - below casing 200mm (8in) Minimum -
In front 600mm (24in) Minimum - At sides
12mm (1/2in) from casing
3.4.2
Maximum heating system contents approx.
76.4 litres (16.8 gals). Acceptance capacity of
expansion vessel 10 litres (2.2 gals).
3.4.3
Means of filling sealed system: to accord with
BS and/or local Water Authority requirements.
3.4.4
The standard concentric horizontal flue allows
a maximum length of duct as follows:
Rear flue: 700mm (wall thickness)
Side flue: 890mm (to centre line of boiler).
Using extension tubes the flue may be ex-
tended to the following lengths.
Concentric
Twin (+ concentric terminal)
The reduction in flue length for each bend
used is listed opposite.
3.5
Electrical Details
Mains supply 230v ~ 50Hz Fused 3A
Internal fuse rating F2A and T100mA
Power consumption:160W
3.6
Performance and Limitations Plus AG
Max. input 34.9 kW (119,080 Btu/h)(net h/w)
Max. inpu 38.7 kW (132.050Btu/h)(grossh/w)
Max. input 34.9 kW (119.080 Btu/h)(net c/h)
Max. input 38.7 kW (132.050Btu/h)(gross c/h)
Min. input 9.95 kW (34.052 Btu/h)(net)(c/h)
Min. input 9.95 kW (34.052 Btu/h)(net)(h/w)
Min. input 11.07 kW (37.770 Btu/h)(gross)(c/h)
Min. input 11.07 kW (37.770 Btu/h)(gross)(h/w)
Max. output 32.00 kW (109,200 Btu/h)(h/w)
Max. output 32.00 kW (109,200 Btu/h)(c/h)
Min. output 9.0 kW (30,700 Btu/h)(h/w)
Min. output 9.0 kW (30,700 Btu/h)(c/h)
Central heating output range
Max. 32.0 kW (109,200 Btu/h)
Min. 9.0 kW (30,700 Btu/h)
Nominal hot water production
Temp. rise of 30
°
C 15.3l/min.
Temp. rise of 35
°
C 13.1l/min.
Gas Pressures
Max. gas pressure 10.1 mbar h/w
Min. gas pressure 1.1 mbar h/w
Gas Rate
Max. 3.69m3/h 138.8 ft3/h (h/w)
Min. 1.05 m3/h 35.6 ft3/h (h/w)
Note: Use gross input values when gas
rating the appliance
Burner Details Main burner:
Polidoro type Main burner injectors 16 x 1.35
3.7
Working Pressure Heating System
Maximum 1.5bar/15m w.g./50ft w.g.
Minimum 0.15bar/1.5m w.g./5ft w.g.
Safety valve setting 3bar/30m/102ft w.g.
3.8
Flow Rates Min. waterflow (dhw) 2.0l/min.
(0.45 gal/min) Min central heating flow rate
through appliance 350litres/hr (1.28 gal/min)
Plus AG
3.0m
3.0m
Horizontal
Vertical
Horizontal
Vertical
Plus AG
14/14m
14/14m