G406s User Guide Document: G406s-2
----------------------------------------------------------------------------------------------------------------------------- ----------------
11
7. System setting: Box ID, RS232, Ethernet
➢
Box ID, RS232 and Ethernet settings can be executed through CH-1 or CH-2.
➢
User can set different IP address in each G406s through Ethernet, USB or remote controller so that
each G406s can be controlled independently. Default IP address is 192.168.0.100.
7.1. Box ID
➢
The range of Box ID is 0 ~ 99 for RS2323 command.
➢
If user uses remote controller to do system operation, the Box ID range is 0 ~ 9.
7.2. RS232 settings
➢
RS232 is designed with DB-9 connector. User can select baud rate between 11520 and 9600.
➢
We can provide UART protocol for the control from RS-232, USB, or Ethernet.
7.3. Ethernet