VMAC - Vehicle Mounted Air Compressors
VMAC Technical Support: 888-241-2289
VMAC Knowledge Base: kb.vmacair.com
28
Connecting the Interior Hoses (Figure 29)
☐
Connect the straight ends of the 3/4 in × 22 in and 3/8 in × 30 in hoses to the
top side of the bulkhead fittings.
☐
Connect the 1/4 in × 25 in PTFE tube to the top side of the bulkhead fitting.
☐
Bundle the PTFE tube and hoses together and route them to the WHASP Tank.
☐
Connect the 90° fitting on the 3/4 in × 22 in hose to the #12 JIC fitting (air/oil
inlet) on the cooler above the fan (Figure 34).
☐
Connect the 90° fitting on the 3/8 in × 30 in hose to the #6 JIC fitting (oil return
fitting) beneath the oil filter on the tank (Figure 34).
☐
Connect the 1/4 in PTFE tube to the 1/4 in push-to-connect (oil scavenge) fitting
near the coalescing filter (Figure 29).
☐
Connect the discharge fitting (#8 male JIC) to the customer’s air system (hose
not supplied).
☐
Secure all hoses, tubes, and wires with P-clips and/or cable ties.
Use of an air receiver tank (minimum 6 USG) is required with this
application.
Follow the instructions on page 44 of this manual to prevent
damage to the system.
Figure 29 — WHASP Tank connections
Discharge to user
tools (#8 JIC)
Oil return
line (#6 JIC)
Air/oil inlet from
compressor (#12 JIC)
1/4 in PTFE
scavenge tube