Problem
Cause
Remedy
The starter motor is not running
Flat battery
Recharge or replace battery
Interrupted electric connection Check the electric connections
Worn brushes
Replace the worn brushes
Apply to an authorised workshop
The engine stops after ignition
Presence of air in the fuel supply
circuit
Carry out bleeding (See “Fuel
supply circuit bleeding”)
Clogged fuel filter
Replace filter (See “Fuel filter
replacement.”)
Injection pump malfunction
Apply to an authorised workshop
faulty fuel pressure regulation
valve
Replace the valve
Apply to an authorised workshop
Presence of air in the fuel supply
circuit
Carry out bleeding (See “Fuel
supply circuit bleeding”)
water and/or impurities in the fuel Apply to an authorised workshop
The electric cables are
disconnected or they do not
guarantee continuity
Check the electric connections
The engine does not reach the
operating speed
Clogged fuel filter
Replace filter (See “Fuel filter
replacement.”)
Presence of air in the fuel supply
circuit
Carry out bleeding (See “Fuel
supply circuit bleeding”)
Injection pump malfunction
Apply to an authorised workshop
Dirty or faulty injectors
Replace the injectors
Apply to an authorised workshop
water and/or impurities in the fuel Apply to an authorised workshop
clogged air filter
Clean or replace the filter
Insufficient combustion air flow
Apply to an authorised workshop
Engine overheating
Apply to an authorised workshop
Overload
Reduce the load
Emission of black smoke from
the exhaust pipe
Dirty or faulty injectors
Replace the injectors
Apply to an authorised workshop
Faulty turbocharging turbine
Replace the turbine
Apply to an authorised workshop