8
4. Lamp Bulb
4.1
lamp bulb
SIRIUS HRI
®
371W
There is high voltage inside the bulb,which may break during operation.The ultraviolet light
emitted by the bulb is harmful to the eyes and skin.Do not stare directly at the fixture during
operation.
1. In order to protect the fixture, please turn off the fixture first when turning off the lamp, and then
disconnect the power after running for at least 5 minutes.
2. Do not touch the bulb with bare hands. Once touched by hand, wipe with alcohol and then dry
with soft linen.
3. When the lamp is on, the bulb operates under high pressure, so there is a risk of rupture. The degree
of danger is related to the length of use time, temperature and unreasonable operation and other factors.
Therefore, please do not use bulbs that exceed the service life.
4. Make sure the bulb is installed in the center to ensure the best results
5.
Fixture settings
4.1
5.1 Main Function
Turn on the machine, press the ENTER button to enter the menu mode, use the UP and DOWN buttons to
find the menu, when the preset menu is displayed on the display, press the ENTER button to confirm, use
the UP and DOWN buttons to select the submenu, press the ENTER button to save the setting Automatically
return to the previous menu. Press the MENU button to return, or wait 30 seconds and automatically exit
the menu mode.
When there is no power connection, press the MENU button for 3 seconds to enter the menu mode. After
setting, press the ENTER button for 1 second or wait for 40 seconds and then automatically exit the setting
function after power off.