![VLTG TV-N380BEAM Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/vltg/tv-n380beam/tv-n380beam_user-manual_1042930014.webp)
14
6.2
6.2 Channel settings
Press the ENTER button to enter the menu mode, select the operating mode → select channel mode, press
the ENTER button to confirm, the current channel mode will flash on the display, use the UP and DOWN
buttons to select the full mode 24 (CH), press the ENTER button to save. Press the MENU button to return
to the previous menu or wait 30 seconds and automatically exit the menu mode.
6.3
6.3 Address code setting
When using a general DMX controller to control fixture, you need to set the starting address (1-512) for the
fixture so that the machine can receive DMX signals.
Press the ENTER button to enter the menu mode, select the DMX function, press the ENTER button to
confirm, the current address will flash on the display, then use the UP/DOWN button to select the address
code (1-512), press the ENTER button to save. Press the MENU button to return to the previous menu or
wait 30 seconds and automatically exit the menu mode.
Please refer to the following chart to set the address codes of the first 4 fixtures
Channel mode
Fixture 1 address
code
Fixture 2 address
code
Fixture 3 address
code
Fixture 4 address
code
Full mode (24 channels)
1
25
49
73
Standard mode (18
channels)
1
19
37
55
Lite mode (15 channels)
1
16
31
46
6.4
6.4 DMX 512 channel
Please refer to the following channel diagram to control
Notice
:
1.IftheDMXsignaliscutoff,thefixturewillremaininthestatebeforethesignalwascutoff,unlessreset.
Channel chart:
Full
mode 24
(
CH
)
Standard
mode 18
(
CH
)
Lite
mode
(15
(
CH
)
Channel
name
Channel value
Features
1
1
1
Horizontal
000-255
0-540 degree
2
2
Horizontal
000-255
16bit Adjustable
3
3
2
Vertical
000-255
0-270 degree
4
4
Vertical
000-255
16bit Adjustable