Страница 1: ...Beam Moving Head Light LX 300 User Manual RDM Color LRD Display Touch Operation Please read the user manual carefully before using ...
Страница 2: ...ue Input 3 3 Setting Boolean Parameters 4 4 Subpage Parameters 4 3 Function Menu Description 5 1 DMX Address Code Settings 5 2 Working Mode Settings 5 3 Panel Display Settings 6 4 Scene Mode 7 5 Parameters Settings 7 6 View Fixture Status of Lighting 8 Chapter 3 Channel Description 10 1 Channel Table 10 Chapter 4 Common Failures and Cautions 13 1 Common Troubleshooting 13 2 Precautions for Use 14 ...
Страница 3: ...uct Precautions To ensure the life of the product do not place the product in a humid or leaky place and do not work in an environment where the temperature exceeds 60 degrees Do not place this product where it is liable to become loose or vibration To avoid the danger of electric shock it need professional people to repair this product When the lamp is used the power supply voltage should not cha...
Страница 4: ...allation you must ensure that the lamp does not fall on the support frame and you need to use a safety rope to pass through the support frame and the lamp handle to ensure safety and prevent the lamp from falling and sliding When the lamp is installed and debugged no pedestrians are allowed to pass under it Regularly check whether the safety rope is worn and the hook screws are loose We will not b...
Страница 5: ...ting system and you can operate by clicking the corresponding item with your fingertip or a blunt object Note Do not tap the display with sharp object to prevent damage Figure 3 Schematic diagram of display panel 2 Menu Operation 1 Select Menu Item The area on the left is the TFT display area and the touch area Use your finger or blunt surface hardware to click on the contents of the panel and you...
Страница 6: ...re at the next boot 3 Setting Boolean Parameters When the parameter set is a Boolean value such as ON or OFF you can directly click the corresponding item to switch the parameter value This type of parameter will be saved to the internal memory after modification Press the parameter option on the right the corresponding option will be grayed out When you release your hand the corresponding paramet...
Страница 7: ...etting There are several operations for setting the address code Select Previous or Next the fixture will automatically calculate the address code of the next or previous device based on the current address code and channel data which can be set quickly Click the address code value to enter the value editing window Here you can set any valid address code The luminaire automatically obtains the cur...
Страница 8: ...cally detects the DMX status and automatically switches the output to prevent data conflicts Host The lamps operate according to the built in If there is no signal from DMX data will be output synchronized otherwise no data will be output Sub host Fixtures run as built in no data is output other fixtures are not synchronized Automatic If there is no signal from DMX the fixture will run as built in...
Страница 9: ...e signal indicator 1 10 10 levels Screen backlight Set the brightness after 10 s of the screen backlight in no operation Full light during operation 1 10 10 levels Touch screen switch Select whether to disable the touch screen When the screen is accidentally damaged you can disable the touch function and use auxiliary input to set the fixture Touch correction When the screen touch is not accurate ...
Страница 10: ...minaire etc Advanced settings X axis reverse X axis reverse settings Close Do not reverse Open reverse Y axis reverse Set Y axis rotation direction Close Do not reverse Open reverse Optocoupler correction Set whether the fixture detects XY out of step and corrects it Close Uncorrected position after out of step Open Automatically correct position after out of step and record out of step failure X ...
Страница 11: ...for judgment as shown in the following table Status information Motor information Display information status of all motors and signals in the light Hall calibrated Not displayed indicating that the motor is not Hall calibrated 0 indicates that the motor is away from the calibration position and 1 indicates that the motor is at the calibration position Status Display motor reset completion status X...
Страница 12: ...ormation and version of the current light an important reference for after sales maintenance device The name of the light the same as the equipment information of RDM model Model of the lamp same as the model information of RDM display board Display board fixed version and serial number Motherboard 1 Fixed version and serial number of motherboard 1 Light source time Record the total accumulated el...
Страница 13: ... 3 Close light 4 103 Slow to fast pulse strobe 104 107 Open light 108 207 Slow to fast strobe 208 212 Open light 213 251 Slow to fast random strobe 252 255 Open light CH8 Dimming 0 255 0 100 Dimming CH9 Color 0 4 White 5 8 White Color 1 9 12 Color1 13 16 Color1 Color2 17 21 Color2 22 25 Color2 Color3 26 29 Color3 30 33 Color3 Color4 ...
Страница 14: ...or6 56 59 Color6 Color7 60 63 Color7 64 67 Color7 Color8 68 71 Color8 72 76 Color8 Color9 77 80 Color9 81 84 Color9 Color10 85 88 Color10 89 93 Color10 Color11 94 97 Color11 98 101 Color11 Color12 102 105 Color12 106 110 Color12 Color13 111 114 Color13 115 118 Color13 Color14 119 122 Color14 ...
Страница 15: ...from slow to fast CH10 Gobo 0 4 White 5 9 Gobo1 10 14 Gobo2 15 19 Gobo3 20 24 Gobo4 25 29 Gobo5 30 34 Gobo6 35 39 Gobo7 40 44 Gobo8 45 49 Gobo9 50 54 Gobo10 55 59 Gobo11 60 64 Gobo12 65 69 Gobo13 70 74 Gobo14 75 127 Flowing from fast to slow 128 130 Stop 131 185 Reverse flow from slow to fast ...
Страница 16: ...ring pattern7 221 225 Slow to fast dithering pattern8 226 230 Slow to fast dithering pattern9 231 235 Slow to fast dithering pattern10 236 240 Slow to fast dithering pattern11 241 245 Slow to fast dithering pattern12 246 250 Slow to fast dithering pattern13 251 255 Slow to fast dithering pattern14 CH11 prism1 0 127 Remove the prism 128 191 prism1 192 255 prism2 CH12 Prism 1 rotation 0 127 0 400 12...
Страница 17: ...r for more than 5 seconds 240 255 Reset for more than 5 seconds Chapter 4 Common Failures and Cautions 1 Common Troubleshooting The lamp contains professional components such as microcomputer circuit boards high voltage power supplies etc For your safety and product life non professionals must not disassemble the lamp and related accessories without authorization 1 Bulb does not light except LED l...
Страница 18: ... The internal circuit enters the protection state and the processing is as follows Check whether the fan is running normally or is dirty causing the internal temperature of the lamp to rise Check whether the internal temperature control switch is closed Check whether the lamp has reached the end of its life and replace it with a new one 5 After the lamp is reset normally it will not be controlled ...
Страница 19: ...tter comply with the scene effect the light should not always be in the current scene that is start the next scene action it is best not to exceed 3 minutes to ensure that multiple fixtures can run synchronously During use if the lamp is abnormal stop using the lamp in time to prevent other faults from being induced 2 RDM Precautions for Use RDM is an extended version of the DMX512 A protocol It i...
Страница 20: ...灯具使用说明书 第 18 页 signal amplifier and then check whether there is a bad contact between the 2 and 3 wires of the signal cable ...
Страница 21: ...灯具使用说明书 第 19 页 ...