background image

ARIAWiFi

SPECIAL SETUP MODE «SETUP MODE / RESET»

To reset the WiFi password or to connect to the fan, the 

SetupMode 

used to edit the settings. To get into the

SetupMode 

to switch, press and hold the button under the cover of the ventilation system for 5 seconds until the LED 

flashes blue. The system is in this mode for 3 minutes, after which it automatically returns to the previous settings. To 

exit setting mode immediately, press and hold the button again for 4 seconds until the LED stops flashing blue and 

starts glowing red. Connect the fan in the

Setup mode 

with a mobile device:

WiFi name: 

Setup mode

WiFi password: 

11111111

To reset the settings to the factory settings, press and hold the button for 14 seconds until the LED flashes red and an 

acoustic signal sounds.

ACCESS BUTTON

The LED can have the following indications

Switched off. 

Normal operation of the device.

Lights up blue. 

Warning that the device is in the 

SetupMode

is switched.

Flashes blue. 

The device is in 

SetupMode

.

Lights up red. 

Warning that the device will be reset to the 

factory settings or the 

SetupMode 

is left.

Flashes red. 

Factory reset completed successfully.

LED

button

15th

Содержание ifan ARIAWiFi

Страница 1: ...Intelligent axial fan OPERATING MANUAL ARIAWiFi ...

Страница 2: ...pe of delivery 6 Technical specifications 6 Assembly and preparation for operation 9 Mains connection 11 Operating rules 11 Fan control 12 Transport regulations 24 Maintenance instructions 25 Manufacturer s guarantee 26 2 ...

Страница 3: ...e operating instructions is believed to be correct at the time this document was written In order to implement current technical developments the company reserves the right to make changes to the design technical properties and scope of delivery of the device at any time No part of this publication may be reproduced transmitted stored in an information search system or translated into any other la...

Страница 4: ...ing and grille Furthermore it must be ensured that there are no foreign bodies in the housing that could damage the impeller blades During assembly make sure that the housing is not deformed Deformation of the housing can cause the motor to stall and loud noises Improper use unauthorized changes and reworking as well as modifications to the device are prohibited Take precautions to ensure that smo...

Страница 5: ...ntal or sensory abilities or without sufficient experience and knowledge if they have been supervised or have been instructed in the safe use of the device and have understood the resulting dangers Do not let children play with the device AFTER ITS SERVICE LIFE THE DEVICE MUST BE DISPOSED OF SEPARATELY THE DEVICE MUST NOT BE DISPOSED OF AS UNSORTED URBAN WASTE 5 ...

Страница 6: ... axial fan made of high quality plastic Ventilation of small to medium sized living spaces that are heated in winter The design of the device is constantly being developed and optimized which is why some models differ from the description in this Operating instructions may differ Supply voltage V Frequency Hz Max Power consumption W Current consumption A Speed min 1 Max Air flow rate m h Electrica...

Страница 7: ...min 1 24 hours Silent Max 24 hours Silent Max 1 6 2 9 5 6 1 7 3 6th 0 02 0 04 0 06 0 03 0 04 0 07 950 1650 2150 850 1350 2200 33 72 106 40 83 133 17th 21 31 17th 22nd 32 100 ARIAWiFi 125 VARIANT FANS Functions model Humidity 24 Trailing counter kcontrol hours switch on hesitation Speed succeeded Ininterval ventilation External counter Motion sensor ARIAWiFi ARIAWiFi Move 7th ...

Страница 8: ...n runs on a low ventilation level to ensure minimal ventilation around the clock When the temperature humidity motion light sensor or an external switch is activated the fan switches to mode Silent or Max Silent Quiet operating mode that is activated by the motion sensor light sensor or an external switch MAX Operating mode of the fan with a high ventilation level which is determined by the humidi...

Страница 9: ... and condensation if it is installed vertically The installation of the fan with a direct air outlet upwards is not permitted 2 Before installation make sure that the device is disconnected from the power supply LN QF 3 Remove the cover from the fan 4 Mark the holes for mounting the fan and power cord 9 ...

Страница 10: ...es and install the wall plugs 6 Mount the fan with the help of the screws 7 Remove the cover to gain access to the terminal box and connect the fan to the power supply according to the connection diagram Reassemble the fan in reverse order 8 Connect the fan to the power supply ON 10 ...

Страница 11: ...LT Control chain of the ventilation level LI Output for connecting the external impedance SK Switch for switching the ventilation level NL N L LT LI SK OPERATING INSTRUCTIONS Degree of protection against ingress of foreign bodies and water ingress IP44 The fan is designed for use in ambient temperatures from 1 C to 45 C The device belongs to the electrical systems of class II 11 ...

Страница 12: ... app connect the mobile device to the fan as a WiFi access point with the name FAN 16 characters of the ID number as indicated on the control board and the housing of the fan Password of the WLAN access point 11111111 Call up the installed app on the mobile device that is connected to the fan If the app is started on a device that is not connected to the fan a message about the missing connection ...

Страница 13: ...ss access point mode select the default connection The connection will be established automatically 4 If the fan is connected to the WLAN home network search for devices in the network 5 The connection is displayed in the list with the ID number of the fan Highlight this 6 Change the connection name if necessary 7 Save the entered data 1 3 5 2 7th 4th 6th 13th ...

Страница 14: ...ode off the desired security mode Enter the details of the home router for the Client Mode on Enter the name of the wireless access point of the home router Enter the password of the WiFi access point of the home router Press the buttonApply Open the WiFi network is not password protected WPAPSK password protected Based onWPA encrypted This technology does not guarantee complete security WPA2 PSK ...

Страница 15: ... the LED stops flashing blue and starts glowing red Connect the fan in theSetup mode with a mobile device WiFi name Setup mode WiFi password 11111111 To reset the settings to the factory settings press and hold the button for 14 seconds until the LED flashes red and an acoustic signal sounds ACCESS BUTTON The LED can have the following indications Switched off Normal operation of the device Lights...

Страница 16: ...ion of the external switch Motion sensor Operating mode Interval ventilation Operating mode Do not bother Switching the valve on off Sensor values Switching the BOOST mode BOOST The timer becomes in the menu Settings timer menu Settings operating modes Max Ventilation level Current temperature Current humidity 14 59 Overrun switch set The Ventilation level is in set 16 ...

Страница 17: ...control unit go to the Settings menu Current time The current time is used to indicate the time and operation of some modes on a schedule see Modes of operation When the fan is disconnected from the power supply the clock continues to run from an external power source 17th ...

Страница 18: ... Resetting the connection with the device can be lost due to the resetting of the Wi Fi settings If necessary set up the WLAN connection again You can also change the settings with the button SetupMode Reset reset to default 2 1 FIRMWARE To view the firmware version go to the Menu firmware This menu shows the current version and the firmware date 18th ...

Страница 19: ...f the temperature sensor Go to the E menusettings sensors set the temperature sensor and activate it It is not possible to set the other sensors Then set the temperature setpoint If the temperature setpoint is exceeded for longer than the switch on delay the fan switches to the high ventilation level MAX to dissipate the excess heat After the room temperature has dropped 4 C below the set target v...

Страница 20: ...ffers the option of changing the humidity setpoint and the ventilation level in automatic mode regardless of which the optimal setpoint for the room in which the fan is located is selected The choice of how the fan works is determined by analyzing the statistical data on humidity Manually manual mode that allows you to set the setpoint in the range of 40 to 80 If the setpoint is exceeded for longe...

Страница 21: ...itch on delay is bypassed If no more movement is registered the lighting switches off with a delay of 1 minute Operation setting of the external switch Go to the menu Settings sensors and activate the external switch If the sensor selection is inactive deactivate the temperature sensor When the connections of the external switch are closed the fan switches to the ventilation stageSilent When the c...

Страница 22: ... output Do not disturb the function is only available when it is activated 24 hours mode to disposal It enables the setting of a time interval in which the fan or switch does not react to sensor tripping and in which the fan runs at the minimum ventilation level Interval ventilation Interval ventilation the function is only available when it is deactivated 24 hours mode available This function ena...

Страница 23: ...ger exceeded Time dependent operation can be ended after the timer has expired when the cause for the sensor mode has ended sensor value for e g relative humidity falls below the set limit value if the Boost button is switched off manually via the app only if the Boost mode is activated when the fan is switched off via the app or the switch on the housing Overrun switch serves to delay the transit...

Страница 24: ... a ventilated room at a temperature of 5 C to 40 C and a relative humidity of up to 70 Vapors and foreign substances in the air which can cause corrosion and damage connection seals are not permitted Use lifting gear when handling cargo to prevent possible damage The transport requirements for this type of cargo must be met The transport with vehicles of any kind must be carried out under constant...

Страница 25: ... the front cover Clean the fan impeller blades with a soft dry cloth or brush Warning The interlock does not take the voltage from the termination terminals of the fan OFF 3 Wash the cover under running water Rub the surface of the front cover dry 4 Set the lock button to the fan operating position Then switch on the fan via the app ON 25th ...

Страница 26: ...sed by the factory that occur within the warranty period the consumer is entitled to free repair of the device s defects by means of warranty repairs by the manufacturer The warranty repair includes in particular work to remedy defects in the operation of the device in order to ensure that the device is used as intended within the warranty period Defects are remedied by replacing or repairing the ...

Страница 27: ...the device Replacement and use of units or parts that are not intended by the manufacturer Inappropriate use of the device Violation of the assembly instructions for the device by the consumer Violation of the regulations for the control of the device by the consumer Connection of the device to a power supply system with a voltage other than that specified in the operating instructions Failure of ...

Страница 28: ...o present the operating instructions with the specified date of purchase Missing receipt with the purchase date which confirms the purchase MEET THE PRESENT OPERATING REQUIREMENTS IN ORDER TO PROPER FUNCTION AND TO ENSURE LONG SERVICE LIFE OF THE DEVICE THE WARRANTY CLAIMS CAN ONLY BE MADE IF THE DEVICE A PROOF OF PURCHASE AND THE OPERATING MANUAL IN WHICH THE DATE OF PURCHASE IS LISTED ARE PRESEN...

Страница 29: ...ARIAWiFi 29 ...

Страница 30: ...ARIAWiFi Certification mark Sold by Name and stamp of Dealer manufacturing date Purchase date 30th ...

Страница 31: ...ARIAWiFi 31 ...

Страница 32: ...VLANO168DE 02 ...