TAP-42X SerieS
19
A.J. Antunes & Co.
P/N 1010976 Rev. G 03/12
maIntenance (continued)
nOte: the system beeps every time a button is pressed.
NOTE: When in normal operating mode, pressing both the ▲ and ▼ buttons displays the current software version.
pOwer lOss tO system (system UnplUGGeD Or sUpply InterrUpteD)
• Any active valve program is aborted
• Valves reset to normal operations (pressurized, water available)
• Control “BeePs” five times every 3 minutes if water flow is present
• If no flow is present for 15 minutes, beeping stops until water flow starts again
• Pressing both ▲and ▼ will silence beeper
flUsH (bUttOn)
Press and hold to run a Flush cycle. The system automatically performs the following stages:
• F1 - Close Permeate Valve - Wait for Flow = 0 gpm or 30 seconds
• F2 - Close Inlet Valve
• F3 - Open Drain Valve - Wait for Flow = 0 gpm or 60 seconds
• F4 - Open Inlet Valve - Wait for 12 seconds
• F5 - Close Drain Valve - Wait for Flow < 3 gpm or 15 seconds
• F6 - Open Permeate Valve
VIew (bUttOn)
Normal Operating Mode
Toggles between UFL cartridge % of life and Carbon Element % of life
VIew (bUttOn) – sensOr reaDInGs
1. Press and hold (in order):
VIew
button and ▼ button.
2. The red System LED illuminates.
3. Press the
VIew
button to scroll through the green leD’s which indicate the following information:
• leD #1 (Top) current actual VeR Value
• leD #2 (Middle) Flow Rate (gpm)
• leD #3 (Bottom) Differential Pressure (psid)
4. To exit Sensor Readings, press the
flUsH
button until red LED turns off.
errOr cODe DescrIptIOns
ec-01
- Differential Pressure = 0 psid
Flow Rate is greater than 0 gpm
ec-08
- Insufficient flush (Tank refill amount is
less than ½ of the discharge amount)
ec-02
- Differential Pressure is greater than 45 psid
(at any flow rate)
ec-09
- Memory data re-initialized
ec-03
- Differential Pressure is greater than 0 psid,
Flow Rate = 0 gpm
ec-10
- Flow switch #1 fail
ec-06
- Flush Flow is less than 0.75 gallon
ec-11
- Flow switch #2 fail
ec-07
- Flow is greater than 10 gpm
ec-12
- Flow switches erratic
ec-13
- EEPROM bad
eVent cODe DescrIptIOns
• eV-20 - Power removed
• eV-21 - Power restored
• eV-22 - Carbon element changed
• eV-23 - UFl Filter changed
• eV-24 - Time exceeded, Flow Rate > 0 gpm
• eV-25-31 - Factory use only