nOte: the system is designed to supply water even with
the power off. However, with power off, the system will
not flush or monitor any usage.
settInG tHe Internal clOcK
After setting the Product Type, the Display flashes "
cl
" indi-
cating that the Internal Clock must be set before any other
action can take place. The unit beeps as a reminder to set
this value. To set the clock:
1. Press and hold (in order) the
VIew
, and ▲ buttons until
the red System LED illuminates and “
--
“ appears on
the display.
2. Release all buttons.
3. Use the ▲ and ▼ buttons to scroll to
01
.
4. Press the
flUsH
button. The Clock Set program uses
the following format for date and time:
YY; MM; DD; HH (0-23); MM
5. Use the ▲ and ▼ buttons to set the local date and
time.
nOte: the system uses military time. If the local time is
3:45 pm on July 2, 2008, the clock would be set as 08; 07;
02; 15; 45.
rinsing the Ultra filter cartridge
The Ultra Filter Cartridge is pre-installed with the TAP System
before shipment. This cartridge
must
be rinsed before placing
the system into operation to remove air and the shipping solu-
tion from the Ultra Filter Cartridge.
Follow these steps to rinse the Ultra Filter Cartridge.
1.
manually
close the Inlet Valve (Figure 11).
2. Make sure a drain hose is connected to the Rinse
Valve. Direct this hose to a drain.
starting the smart controller
nOte: make sure that all ball valves are closed before
starting the system.
Follow these steps to power up the system:
1. After the system is mounted, connect the power supply
to the bottom right of the Smart Controller (Figure 4).
2. Select the appropriate adaptor for your power outlet
and attach the adapter to the transformer.
3. Plug the transformer into the appropriate outlet that has
power to it at all times.
nOte: Do nOt plug the power transformer into an outlet
that will be switched off. failure to supply power to the
system at all times may result in short cartridge life or
bad tasting water.
ULTRAFILTER
1
2
3
VIEW
CARBON
SYSTEM
NO FLUSH DURING PEAK
% REMAINING
ULTRAFILTER
CARBON
CHANGE
figure 10. tap system control panel
system
Display
3.
manually
open the Rinse Valve (Figure 11).
4. Enter the
06
program
.
Press and hold (in order) the
VIew
, and ▲ buttons until the red
system
LED illumi-
nates and “
-- ”
appears on the display (Figure10).
nOte: Ultra filter cartridge must be rinsed to drain
before use. rinsing to drain removes storage solution
and air. Do nOt rinse into carbon if present. carbon life
and/or performance may be affected.
5. Use the ▲ button to scroll up to “
06
” and press the
flUsH
button to start the rinse program. The system
displays
d3
and begins to depressurize.
6.
manually
open the Inlet Valve. Press the
flUsH
button to start the
r1
stage.
7. Wait until the display flashes
r1
(approximately 1
minute). The system beeps.
8. Press the
flUsH
button. The system starts the
r2
stage.
9. Wait until the display flashes
r2
(approximately 15
minutes) The system beeps.
10.
manually
close the Rinse Valve.
11. Press the
flUsH
button to start the
r3
stage.