background image

 

 

VXO4852GBF 

INSTALLATION GUIDE

 
 

 

PAGE 3 of 5

 

 

 
 

AIR TANK 

MOUNTING 

  Find a convenient mounting location in your vehicle for the air tank. Ensure ports are reachable before drilling 

any holes. 

  Mark the location of holes using the mounting bracket of the air tank as a template, and then drill to size.  

  Using mounting hardware provided, secure the air tank. 

IMPORTANT

: Do not mount on a flexible material. 

 

The installation location of your tank’s accessories depends on your air system’s configuration.

 

 

PORT LOCATIONS AND THREAD SIZE (NPT) 
 

 

 

PRESSURE SWITCH RATING 

 

The included pressure switch has a rating of 170 PSI ON, 200 PSI OFF. When the air pressure in the air tank 
is below the preset ON pressure (170 PSI), the compressor will automatically turn on and will start pumping 
air into the tank. When the pressure reaches the cut OFF pressure (200 PSI), the compressor will be 
automatically shut off.

 

 

DRAIN VALVE 

  This valve helps you drain the water that can collect in the air tank after long periods of use. 

REMOVING CONDENSATION

 

To remove any condensation which has accumulated inside the tank, bleed the tank’s pressure until it ranges 
from approximately 5 PSI to 20 PSI. 

 

Remove the drain valve found at the tank’s bottom to drain the water from the tank. After draining the 
accumulated condensation, reinstall the drain valve. 

 

IMPORTANT

: Draining the system regularly will extend the life of the air tank. 

 

WATER TRAP 

INSTALLATION 

  Start installation with the bowl detached from the filter body. 

  Connect the stainless steel braided hose of the compressor to the inlet port of the water trap. 

  Using the male coupling on the outlet port of the water trap, connect the water trap to the air tank. 

  When screwing the fittings together, prevent ingress of shavings and sealant to the interior of the unit. 

Contaminations in the unit may cause it to fail. 

  Make sure that all connections to the filter are tight and secure. 

  Push bowl into the filter body and turn fully clockwise before pressurizing. 

OPERATION 

  Let the filter run with air supply on. Ensure that the pressure to the air inlet of the filter from air line does not 

exceed the maximum pressure specified in the instructions. 

  The filter is equipped with a manual drain. Turn manual drain valve to drain accumulated liquids inside the 

bowl. Take care to drain the liquids from the bowl whenever necessary and always keep the liquids below the 
baffle. 

Отзывы: