APPENDIX C
Event Messages
64
132
Zone up then down
The zone state has cycled
through the “up” and “down”
states several times. Current
zone state (at the time of this
message) is down.
---
Warning
133
Zone down then up
The zone state has cycled
through the “up” and “down”
states several times. Current
zone state (at the time of this
message) is up.
---
Warning
140
Port inserted
A port was inserted onto the
zone (after being bypassed).
---
Info
141
Port bypassed
(LIPF8)
A port was bypassed (could not
insert) because a LIP(F8) was
received at port input. (A
LIP(F8) indicates a loop fail-
ure.)
Check all connections
for the specified port.
Info
142
Port bypassed (tx
fault)
A port was bypassed because
the switch detected a transmit-
ter fault on the port’s trans-
ceiver.
Contact an authorized
service representative.
The transceiver may
need replacing.
Info
143
Port bypassed
(timeout)
A port was bypassed (could not
insert) because no LIP(F7)s
were received after continuous
transmission of LIP(F7)s for
112 milliseconds.
---
Info
145
Port bypassed
A port was bypassed for a rea-
son other than transceiver
transmitter fault, invalid
response, or manual bypass.
---
Info
146
Port bypassed then
inserted
A port was bypassed, then
inserted.
---
Info
147
Port inserted then
bypassed
A port was inserted, then
bypassed.
---
Info
150
Transceiver inserted
A transceiver was inserted.
---
Notice
151
Transceiver removed A transceiver was removed.
---
Notice
160
Management active
Agent is operational.
---
Info
165
Agent task asserted
on prev exec cycle
During normal operations, an
attempt to execute a command
was aborted due to an internal
error in the firmware.
The switch automatically resets
after the occurrence.
Contact an authorized
service
representative.
Critical
166
Agent machine
exception on prev
exec cycle
A task attempted to execute an
unknown command. The
switch automatically resets
after the occurrence.
Contact an authorized
service
representative.
Critical
170
Diagnostic function
aborted
A diagnostic setting is miscon-
figured and required a firm-
ware override.
Check diagnostic set-
tings for incompatibili-
ties.
Warning
200
CRC error detected
CRC errors were detected in a
frame received on a port.
No action required. You
can modify the CRC
Error threshold through
the Web Manager or
CLI interface.
Info
201
CRC error threshold
exceeded
During the past ten seconds, the
number of CRC errors in
frames received by the specified
port exceeded the current
threshold value.
No action required. You
can modify the Error
Count threshold through
the Web Manager or
CLI interface.
Info
202
OS Error threshold
exceeded
During the past ten seconds, the
number of OS errors (invalid
transmit words, or 8b/10b
encoding errors) in frames
received by the specified port
exceeded the current threshold
value.
No action required. You
can modify the Error
Count threshold through
the Web Manager or
CLI interface.
Info
Ref
Event
Message
Meaning
Action
Severity