Vixel Model 335 Installation & Configuration Guide
CHAPTER 3
Management
36
U s i n g t h e C o m m a n d L i n e I n te r fa c e (C L I )
The Command Line Interface (CLI) allows you to complete several switch management
tasks over Ethernet through a telnet session or through a direct serial link. While both
the CLI and Web Manager interfaces allow you to view switch information and
configure switch settings, the CLI also allows you to enable or disable DHCP requests,
change the CLI/Web Manager password, manage traps, and complete several other
switch management functions.
Connecting to the CLI
Note: You may have up to
10 concurrent telnet
sessions accessing the
switch.
You can connect to the CLI over the telnet interface or the serial link interface.
To connect over Ethernet through telnet interface:
1. Make sure the Vixel Managed Switch is connected to an Ethernet network via the
switch’s Ethernet connection and that the monitoring workstation can access this
Ethernet network.
2. Make sure that you know the switch’s IP address before connecting to the CLI. (the
default IP Address is
0.0.0.0
)
3. At a command line prompt, type
telnet
IP
(where
IP
is the switch’s IP address).
You are now connected to the CLI and ready to log on.
To connect through a serial link:
1. Attach one end of an RS-232 null modem cable to the serial port on the workstation;
attach the other end to the RS-232 port on the switch.
2. For Unix workstations, type the following command at a Unix prompt (where
SerialPortDevicePath
is the filepath to the serial port used for connection):
cu -s 19200 -b 8 -1 SerialPortDevicePath
3. For Windows® platforms, open a terminal session through a terminal emulation
program (such as HyperTerminal) with the appropriate serial port (for example,
COM1) and the following serial port parameters:
• Bits per second: 19200
• Data bits: 8
• Parity: None
• Stop bits: 1
• Flow control: Xon/Xoff
You are now connected to the CLI and ready to log on.
Logging On and Off
To log onto the CLI (once connected as shown above), type
li
at the prompt, then type
the password (the default password is
password
).
To log off the CLI, type
lo
at the prompt.
Make sure you change the password after you log on the first time.