![Vixel InSpeed 335 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/vixel/inspeed-335/inspeed-335_installation-and-configuration-manual_1041067035.webp)
Vixel Model 335 Installation & Configuration Guide
CHAPTER 3
Management
32
The Zone Information page displays the current zoning configuration, the ports in each
zone, the zone state, the init count, and the time duration ("up time") for the zone. The
displayed settings are listed below:
Overlapping Zones
Overlapping zoning can only be implemented in Zone 1 and the switch must be
operating in switching mode. To participate in overlapping zoning, each port must have
their cascade mode configured to "auto".
If the switch is operating using non-overlapping zoning, you can still configure
overlapping zoning within the default zone. If a LIP occurs on any port in the default
zone, it will affect every port in the default zone, regardless of any overlapping zone
configurations. Overlapping zones do not support LIP isolation.
To view the overlapping zoning, click Overlapping. The Overlapping Zone 1
Information page appears.
Figure 3-25. Overlapping Zone 1 Information Page
Setting
Description
Zone number
The zone number on the switch (1-12).
Port number(s)
The port numbers that are assigned to the specified zone.
Zone state
The current state of the zone; either "up" or "down".
Init Count
The number of times a zone has transitioned from an "down" state to
an "up" state.
Up Time
The amount of time that the zone has been operational.
Содержание InSpeed 335
Страница 1: ...Managed Storage Switch InSpeed Model 335 INSTALLATION CONFIGURATION guide ...
Страница 60: ...57 Appendixes ...