OSD MENU SETTING
F. TOUR SET
8 Programmable tours can be set and each tour can have up to 64 preset steps. After setting up the
tours the 71~78 + preset buttons launch group tours # 1~8
TOUR SET
TOUR NO :
01
TOUR TITLE
: TOUR01
TOUR STEP
: 01
PRESET NO.
: 01
DWELL TIME
: 03
SPEED
:
200
°
/S
SAVE
EXIT
DEFAULT SETTING
F-1.
TOUR SET – TOUR NO.
Up to 8 group tours can be programmed.
F-2.
TOUR SET – TOUR TITLE
To set a tour title, use the joystick left/right or pan left/right keys. Each title can have up to 16
characters.
Press ZOOM TELE button to move the next character from left to the right and ZOOM WIDE
button to move the next character from right to left (Space displays when
appears) The tour title
is not displayed on the monitor and is only for the reference of user.
F-3.
TOUR SET – TOUR STEP
Each tour group consists of up to 60 preset steps with different dwell time and speed. It is possible
to match any preset # for any tour step.
F-4.
TOUR SET – PRESET NO.
For each tour step it is possible to select any preset number up to 64. The default setting is BLK
F-5.
TOUR SET – DWELL TIME
Dwell time can be programmed from 1-99 seconds. The default setting is 03 seconds.
F-6.
TOUR SET – SPEED
Each tour step can be set with a different speed up to 200°/S and it is selectable from 10°/S. The
default setting is 200°/S.
F-7.
TOUR SET – SAVE
To save the memorized data and escape this page, move the joystick right or press the pan
right key when cursor is at SAVE
F-8.
TOUR SET – EXIT
To escape this page, move the joystick right or press the pan right key.