VIVOTEK
284 - User's Manual
trigger boot,
di,
pir,
motion,
seq,
recnotify,
tampering,
vi,
volalarm,
visignal,
vadp,
smartsd
<product dependent>
6/6
Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“pir”= PIR detection
“motion” = Video motion detection
“seq” = Periodic condition
“visignal” = Video input signal loss.
“recnotify” = Recording notification.
“tampering” = Tamper detection.
“vi”= Virtual input (Manual trigger)
“volalarm”= Audio detection
“smartsd”= Lifetime detection of SD card
triggerstatus
string[40]
6/6
The status for event trigger
di
0,<positive integer>
6/6
Indicate the source id of di trigger.
This field is required when trigger condition is
“di”.
One bit represents one digital input. The LSB
indicates DI 0.
mdwin
0,<positive integer>
6/6
Indicate the source window id of motion
detection.
This field is required when trigger condition is
“md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows,
set mdwin as 5.
mdwin0
0,<positive integer>
6/6
Similar to mdwin. The parameter takes effect
when profile 1 of motion detection is enabled.
vi
0,<positive integer>
6/6
Indicate the source id of vi trigger.
This field is required when trigger condition is
“vi”.
One bit represents one digital input. The LSB
indicates VI 0.