38
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
time zone.
daylight_auto_begintim
e
string[19]
6/7
Display the current daylight saving start
time.
daylight_auto_endtime string[19]
6/7
Display the current daylight saving end
time.
daylight_timezones
string
6/6
List time zone index which support
daylight saving time.
updateinterval 0,
3600,
86400,
604800,
2592000
6/6
0 to Disable automatic time adjustment,
otherwise, it indicates the seconds
between NTP automatic update
intervals.
utctime
<string>
6/7
Current UTC timestamp.
* We support this parameter when the
version number (httpversion) is equal or
greater than 0314b.
tz
<POSIX TZ
string>
6/6
POSIX timezone setting.
* We support this parameter when the
version number (httpversion) is equal or
greater than 0314b.
restore 0,
<positive
integer>
7/6
Restore the system parameters to default
values after <value> seconds.
reset 0,
<positive
integer>
7/6
Restart the server after <value> seconds
if <value> is non-negative.
restoreexceptnet 0,
<positive
integer>
7/6
Restore the system parameters to default
values except (ipaddress, subnet, router,
dns1, dns2, pppoe).
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to the
default value except for a union of the
combined results.
restoreexceptdst
0,
7/6
Restore the system parameters to default
© 2020 VIVOTEK INC. All Right Reserved
39
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
<positive
integer>
values except all daylight saving time
settings.
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to default
values except for a union of combined
results.
restoreexceptlang 0,
<positive
integer>
7/6
Restore the system parameters to default
values except the custom language file
the user has uploaded.
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to the
default value except for a union of the
combined results.
restoreexceptvadp 0,
<positive
integer>
7/6
Restore the system parameters to default
values except the vadp parameters and
VADP modules that stored in the system.
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to the
default value except for a union of the
combined results.
restoreexceptfocusvalu
e
0,
<positive
integer>
7/6
Restore the system parameters to default
values except zoom and focus value.
This command can cooperate with other
“restoreexceptXYZ” commands. When
cooperating with others, the system
parameters will be restored to the
default value except for a union of the
combined results.
* Only available when
"capability_image_c<0~(n-1)>_remotefo