VIVOTEK
User's Manual - 151
i<0~(m-1)>_begintime
hh:mm
18:00
4/4
Begin time of
schedule mode.
i<0~(m-1)>_endtime
hh:mm
06:00
4/4
End time of
schedule mode.
i<0~(m-1)>_win_i<0~2>_enable
<boolean>
0
4/4
Enable motion
window.
i<0~(m-1)>_win_i<0~2>_name
string[14]
<blank>
4/4
Name of
motion window.
i<0~(m-1)>_win_i<0~2>_left
0 ~ 320
0
4/4
Left coordinate
of window
position.
i<0~(m-1)>_win_i<0~2>_top
0 ~ 240
0
4/4
Top coordinate
of window
position.
i<0~(m-1)>_win_i<0~2>_width
0 ~ 320
0
4/4
Width of
motion
detection
window.
i<0~(m-1)>_win_i<0~2>_height
0 ~ 240
0
4/4
Height of
motion
detection
window.
i<0~(m-1)>_win_i<0~2>_objsize
0 ~ 100
0
4/4
Percent of
motion
detection
window.
i<0~(m-1)>_win_i<0~2>_sensitivity
0 ~ 100
0
4/4
Sensitivity of
motion
detection
window.
7.17 Tempering detection settings
Group:
tampering_c<0~(n-1)>
for n channel product
(capability.tampering > 0)
NAME
VALUE
DEFAULT
SECURITY
(get/set)
DESCRIPTION
enable
<boolean>
0
4/4
Enable or disable tamper detection.
threshold
0 ~ 255
32
4/4
Threshold of tamper detection.
duration
10 ~ 600
10
4/4
If tampering value exceeds the ‘threshold’ for