VIVOTEK
170 - User's Manual
notifyserver
0~31
0
6/6
Indicate which notification server is
scheduled.
One bit represents one application
server (server_i0~i4).
bit0 (LSB) = server_i0.
bit1 = server_i1.
bit2 = server_i2.
bit3 = server_i3.
bit4 = server_i4.
For example, enable server_i0,
server_i2, and server_i4 as
notification servers; the notifyserver
value is 21.
weekday
0~127
127
6/6
Indicate which weekday is
scheduled.
One bit represents one weekday.
bit0 (LSB) = Saturday
bit1 = Friday
bit2 = Thursday
bit3 = Wednesday
bit4 = Tuesday
bit5 = Monday
bit6 = Sunday
For example, to detect events on
Friday and Sunday, set weekday as
66.
begintime
hh:mm
00:00
6/6
Start time of the weekly schedule.
endtime
hh:mm
24:00
6/6
End time of the weekly schedule.
(00:00~24:00 indicates schedule
always on)
prefix
string[16]
<blank>
6/6
Indicate the prefix of the filename.
cyclesize
200~
100
6/6
The maximum size for cycle
recording in Kbytes when choosing to
limit recording size.
(not used in FD8362E)
reserveamount
0~
100
6/6
The reserved amount in Mbytes
when choosing cyclic recording
mechanism.