VIVOTEK
290 - User's Manual
7.41 UART control
Group:
uart
(capability.nuart > 0 and capability.fisheye = 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40]
1/4
Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128]
1/4
Full path of the PTZ driver.
enablehttptunnel
<boolean>
1/4
Enable HTTP tunnel channel to control UART.
Group:
uart_i<0~(n-1)>
n is uart port count
(capability.nuart > 0 and capability.fisheye = 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600,1200,
2400,3600,4800,72
00,9600,19200,384
00,57600,115200
4/4
Set baud rate of COM port.
databit
5,6,7,8
4/4
Data bits in a character frame.
paritybit none,
odd,
even
4/4
For error checking.
stopbit
1,2
4/4 1
2-1.5 , data bit is 5
2-2
uartmode rs485,
rs232
4/4
RS485 or RS232.
customdrvcmd_i<0~9>
string[128]
1/4
PTZ command for custom camera.
speedlink_i<0~4>_name string[40]
1/4
Additional PTZ command name.
speedlink_i<0~4>_cmd
string[40]
1/4
Additional PTZ command list.
ptzdriver 0~19,
127 (custom),
128 (no driver)
1/4
The PTZ driver is used by this COM port.