![Vivax PH-1500D B Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/vivax/ph-1500d-b/ph-1500d-b_user-manual_1038202059.webp)
VIVAX
ENG
10
seconds then stops flickering, and the displayed
temperature is always
brighten (in non-extinguishing condition).
ANTI FREEZE MODE
Keep pressing the "
MODE
" key, the heater enters into the Anti-Freezing Mode, the
icon is brightened and automatically set the temperature at 5°C. In this condition,
you can't shift Heating power but you can switch between shutdown and start-up by
pressing the "
ON/OFF
" key and the temperature can't be set by pressing the "
+
" or "
-
" key, and the heater always works with low power. The heater works at the following
state under the Anti-Freezing Mode:
A: The heating elements stop working when the indoor temperature
Th
is higher than
or equal to 5°C, the icon turns off and the displayed temperature 5°C flickers for
10 seconds then stops flickering, and the displayed temperature is always brighten
(in non-extinguishing condition).
B: The heating elements keep working and the icon will be brightened again when
Th
is lower or equal to 3°C.
Keep pressing the "
MODE
" key, the heater returns to the Normal Mode, and you can
switch the working mode circularly by pressing the "
MODE
" key repeatedly.
TIMER Settings
The heater enters into the timer setting interface. You can press the "
+
" or "
-
" key to
set the time shutdown. In this condition, the icon is brightened and the timer setting
begins to flickering. The timer can be performed in any mode. The corresponding icon
and gear shall be displayed during the time setting. The time setting range is
0-24h
,
and the adjustment step is
1h
. When the value is set as
0H
, the timing is canceled;
when the set value is not
0H
, the timer is active. The time setting will be regularly reset
if the heater turns off within the setting time. Under power Off state, press the "
TIMER
"
key, the heater enters into the timer setting interface. You can press the "
+
" or "
-
" key
to set the time start-up. In this condition, the icon is brightened and the timer setting
begins to flickering. Other icons are not brightened and the other functions are the
same as the power on state.
After reaching the setting time, the heater turns on and enters into the working mode
before it last shutdown, but the buzzer will not activated.
MEMORY FUNCTION
Power On the heater again after it is shut down normally, the heater will work as the
latest working mode state before shutdown. Shut down under the normal working
mode, the heater will work as the normal working mode after power On.
Power Off, power On again, the heater works under the normal working mode.
ERROR CODES AND SPECIAL UNIT SETTINGS
A. Protection function for the short circuit and open circuit of the temperature
sensor
Under any mode, if the short circuit protection occurs to the temperature sensor,
the digital screen displays the room temperature and the digital tubes display E1
and flicker continuously, any keystroke operation is invalid.
B. Safety protection function
When the heater is turned on, and the indoor temperature Th exceeds 50°C, all the
output will be closed, and all LED lights flicker "
FF
" by frequently of 1/s. In this
condition, the heater can’t be turned on and all operations will be invalid even if the
indoor temperature is less than 50°C.
Содержание PH-1500D B
Страница 62: ...VIVAX ...
Страница 80: ...www VIVAX com ...