1:Indoor or Outdoor DC Fan Motor(control chip is in fan motor)
Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in fan motor
connector. If the value of the voltage is not in the range showing in below table, the PCB must has
problems and need to be replaced.
DC motor voltage input and output
NO. Color Signal
Voltage
1 Red Vs/Vm 280V~380V
2 --- ---
---
3 Black GND
0V
4 White Vcc
14-17.5V
5 Yellow Vsp
0~5.6V
6 Blue FG
14-17.5V
2.
Outdoor DC Fan Motor (control chip is in outdoor PCB)
Power on ,and check if the fan can run normally, if the fan can run normally, the PCB must has
problems and need to be replaced, If the fan can’t run normally, measure the resistance of each two
pins. If the resistance is not equal to each other, the fan motor must have problems and need to be
replaced, otherwise the PCB must has problems and need to be replaced.
3. Indoor AC Fan Motor
Power on and set the unit running in fan mode at high fan speed. After running for 15 seconds,
measure the voltage of pin1 and pin2. If the value of the voltage is less than 100V(208~240V power
supply)or 50V(115V power supply), the PCB must has problems and need to be replaced.
Содержание Mission Inverter Series
Страница 12: ...Mission Inverter DM16 01 01 22en 12 Service manual For MSMBAU 09HRFN1 BW For MSMBBU 12HRFN1 BW ...
Страница 13: ...DM16 01 01 22en Mission Inverter Service manual 13 For MSMBCU 18HRFN1 BW For MSMBDU 24HRFN1 BW ...
Страница 17: ...DM16 01 01 22en Mission Inverter Service manual 17 For MOCA01 24HFN1 ...
Страница 24: ...Mission Inverter DM16 01 01 22en 24 Service manual MOBA02 09HFN1 MOB03 12HFN1 ...
Страница 25: ...DM16 01 01 22en Mission Inverter Service manual 25 MOB02 18HFN1 MOCA01 24HFN1 ...