Compressor
overcurrent
protection
1.
The
same
reason
to
P1.
2.
Power
supply
voltage
of
the
unit
is
low,
increase
the
power
voltage
to
the
required
range
High
discharge
temperature
protection
1.
The
same
reason
to
P1.
2.
TW_out
temp.sensor
is
loosen
Reconnect
it.
3.
T1
temp.sensor
is
loosen.
Reconnect
it.
4.
T5
temp.sensor
is
loosen.
Reconnect
it
DC
fan
motor
protect
Contact
your
local
dealer
High
temperature
protection
of
refrigerant
outlet
temp
of
condenser
1.
Heat
exchanger
cover
is
not
removed.
Remove
it.
2.
Heat
exchanger
is
dirty
or
something
is
block
on
the
surface.
Clean
the
heat
exchanger
or
remove
the
obstruction.
3.
There
is
no
enough
space
around
the
unit
for
heat
exchanging.
4.
Fan
motor
is
broken,
replace
a
new
one
Transducer
module
temperature
too
high
protect
1.
Power
supply
voltage
of
the
unit
is
low,
increase
the
power
voltage
to
the
required
range.
2.
The
space
between
the
units
is
too
narrow
for
heat
exchange.
Increase
the
space
between
the
units.
3.
Heat
exchanger
is
dirty
or
something
is
block
on
the
surface.
Clean
the
heat
exchanger
or
remove
the
obstruction.
4.
Fan
is
not
running.
Fan
motor
or
fan
is
broken,
Change
a
new
fan
or
fan
motor.
5.
Water
flow
rate
is
low,
there
is
air
in
system,
or
pump
head
is
not
enough.
Release
the
air
and
reselect
the
pump.
6.
Water
outlet
temp.sensor
is
loosen
or
broken,
reconnect
it
or
change
a
new
one.
Содержание HPS-120HM155AERI/I1s
Страница 2: ......
Страница 60: ... HR VIVAX 57 DODATAK B Dijagram ožičenja s električnim upravljanjem 4 10kW ...
Страница 64: ... HR VIVAX 1 ...
Страница 95: ...VIVAX HR 32 STRUKTURA IZBORNIKA PREGLED ...
Страница 96: ... HR VIVAX 33 ...
Страница 129: ...VIVAX ENG 28 Electronic control box 12 14 16 kW 1 phase ...
Страница 159: ...VIVAX ENG 58 ANNEX B Electrically controlled wiring diagram 4 10kW ...
Страница 163: ......
Страница 164: ... ENG VIVAX 1 ...
Страница 195: ...VIVAX ENG 32 MENU STRUCTURE OVERVIEW ...
Страница 196: ... ENG VIVAX 33 ...
Страница 229: ...ZZZ 9 9 FRP ...