ENG
VIVAX
Adjustment of minimum level of the flame
1. Turn the taps down to minimum.
2. Remove the knob from the tap and place a
small bladed screwdriver in the centre of the
tap shaft.
3. The correct adjustment is obtained when the
flame has a length of about 6 - 7 mm.
For butane / propane gas (LPG), turn the screw
clockwise. Refit the control knob.
For natural gas, turn the screw one time
counter clockwise. At low position, length of
normal flame should be 6-7 mm
Make sure that the flame does not go out by
quickly turning from maximum flow to minimum
flow. If it does then remove the control knob and
make further adjustments to the gas flow,
testing it again once the adjustment has been
made.
4. Repeat this process for each one of the gas
taps.
IMPORTANT
Do not dismantle the tap shafe: in the event of malfunction, change the whole tap.
Before placing the burners back on the top place, make sure that the injector is not
blocked.
A full operational test and a test for possible leakages must be carried out after gas
conversion (such as soap water or gas detector).
After completing conversion, a qualified technician or installer has to mark “V” on the
right gas category to match with the setting in rating plate. Remove the previous
setting “V” mark.
Control Handle
Tap
Sealing
ring
Adjustment
screw
Содержание BH-31TEI X
Страница 2: ...VIVAX ...
Страница 68: ...VIVAX ...
Страница 69: ...МК Упатство за употреба Гарантен лист Сервисни места BH 31TEI X BH 31TVCCI G BH 40TEI G BH 40TEI GW ...
Страница 102: ...VIVAX ...
Страница 103: ...AL Udhëzime për shfrytëzim Fletë garancie Serviset e autorizuar BH 31TEI X BH 31TVCCI G BH 40TEI G BH 40TEI GW ...
Страница 136: ...VIVAX ...
Страница 137: ...SLO Navodila za uporabo Garancijska izjava Servisna mesta BH 31TEI X BH 31TVCCI G BH 40TEI G BH 40TEI GW ...
Страница 169: ...EN User manual BH 31TEI X BH 31TVCCI G BH 40TEI G BH 40TEI GW ...
Страница 201: ...VIVAX ENG ...
Страница 202: ...VIVAX ...
Страница 219: ...VIVAX ...
Страница 220: ...www VIVAX com ...