Room size
Ventilating opening
Smaller than 5m
3
Min. 100 cm
2
Between 5m
3 –
10m
3
Min. 50 cm
2
Bigger than 10m
3
No need
In basement or Cellar
Min. 65 cm
2
Connection and Security:
1. Prior to installation, ensure that the local distribution conditions
(nature of the gas and gas pressure) and the adjustment of the
appliance are compatible
2. The adjustment conditions for this appliance are stated on the label
(or data plate)
3. This appliance is not connected to a combustion products
evacuation device. It shall be installed and connected in
accordance with current installation regulations. Particular
attention shall be given to the relevant requirements regarding
ventilation
4. Fit the clamp to the hose. Push one of the hose until it goes to the
end of the pipe.
5. For the sealing control; ensure that the control buttons in the
control panel are closed, but the gas cylinder is open. Apply some
soap bubbles to the connection. If there is gas leakage, there will
be foaming in the soaped area.
6. The cooker should be using a well ventilation place and should be
install on flat ground.
7. Re-inspect the gas connection.
Содержание BH-31TEI X
Страница 2: ...VIVAX ...
Страница 68: ...VIVAX ...
Страница 69: ...МК Упатство за употреба Гарантен лист Сервисни места BH 31TEI X BH 31TVCCI G BH 40TEI G BH 40TEI GW ...
Страница 102: ...VIVAX ...
Страница 103: ...AL Udhëzime për shfrytëzim Fletë garancie Serviset e autorizuar BH 31TEI X BH 31TVCCI G BH 40TEI G BH 40TEI GW ...
Страница 136: ...VIVAX ...
Страница 137: ...SLO Navodila za uporabo Garancijska izjava Servisna mesta BH 31TEI X BH 31TVCCI G BH 40TEI G BH 40TEI GW ...
Страница 169: ...EN User manual BH 31TEI X BH 31TVCCI G BH 40TEI G BH 40TEI GW ...
Страница 201: ...VIVAX ENG ...
Страница 202: ...VIVAX ...
Страница 219: ...VIVAX ...
Страница 220: ...www VIVAX com ...