9. Pipe preparation
INSTALATION INSTRUCTIONS
9.1
PIPE & ELECTRICAL WIRE CUTTING
•
Use cutting tools easily found in the market.
•
Measure precisely both outer & inner pipe.
•
Provide a little bit longer pipe than the measurement.
•
Wire must be 1.5 m. longer than the refrigerant tube.
9.2
REAMING
• Clean inside of the inner refrigerant tube.
• While reaming, the tube end must be on the top of
the reamer to prevent any dust going back into the
tube.
9.3
FLARING THE PIPE END
• Flare both ends of the pipe with flaring kit by fitting the
flare nut on the pipe before flaring. Set the die on the
pipe so that pipe end is 0.5 mm. above top of the die.
Check if the pipe end is even and perfectly round.
9.4
WIRE
CONNECTION
AND
TAPE
COVERING
(see the picture on the right side)