Installation of indoor unit
INSTALATION INSTRUCTIONS
Checking for gas leakage
1)Check for leakage of gas after air purging
2)See the sections on air purges and gas leak checks in the installation
manual for the outdoor unit
Attaching the connection pipe
• Attach the pipe after checking for gas leakage, described above.
1)Cut the insulated portion of the on-site piping, matching it up with the connecting portion.
2)Secure the slit on the refrigerant piping side with the butt joint on the auxiliary piping using the tape, making
sure there are no gaps
3)Wrap the slit and butt joint with the included insulation sheet, making sure there are no gaps
CAUTION
1. Insulate the joint of the pipes securely.
Incomplete insulation may lead to water leakage.
2. Push the pipe inside so it does not place undue force on the front grille
Connecting the drain hose
Insert the supplied C drain hose into the
socket of the drain pan.
Fully insert the drain hose until it
adheres to a seat of the socket
Check for leakage here
•
Apply soapy water
and ch-
eck carefully for
leaking gas.
•
wipe soapy water
off after
the check is
complete.
Содержание ACP-12CT35GEEI
Страница 2: ......
Страница 3: ...HR BiH Upute za uporabu RoHS 13 ACP 12CT35GEEI ACP 18CT50GEEI ...
Страница 33: ...SR BiH Korisničko uputstvo RoHS 13 ACP 12CT35GEEI ACP 18CT50GEEI ...
Страница 62: ...MAK Упатства за употреба RoHS 13 ACP 12CT35GEEI ACP 18CT50GEEI ...
Страница 63: ......
Страница 92: ...AL Udhëzime për përdorim RoHS 13 ACP 12CT35GEEI ACP 18CT50GEEI ...
Страница 93: ......
Страница 122: ...ENG User manual RoHS 13 ACP 12CT35GEEI ACP 18CT50GEEI ...
Страница 123: ......
Страница 151: ...www vivax com ...
Страница 152: ...www vivax com 66129914161 ...