Controller Function Manual
Indoor ambient temperature (T
amb.
)
1 Temperature Parameters
2 Basic Functions
2.1 Cooling Mode
1.Temp. can be set in the range of 16-30 .
2. The unit will firstly run at high fan speed for 8s and then switch to preset fan speed.
2.2 Dehumidifying Mode
2.3 Fan Mode
2. If compress stops at required temp. point,indoor fan will run by blowing residual heat.
2.5 AUTO Mode
1) When Tamb. , the unit runs under cooling mode, Tpreset=25 . (Tpreset=26 ,connected withwire contrller.)
Evaporator tube temperature (T
tube
)
3. When error of outdoor unit occurs or the unit stops for protection, indoor unit will keep its orignal operating state.
1.Temp. can be set in the range of 16-30 .
2. The unit will firstly run at high fan speed for 8s and then switch to low fan speed.
3. When error of outdoor unit occurs or the unit stops for protection, indoor unit will keep its orignal operating state.
1.Temp. can be set in the range of 16-30 .Setting temp on wire controller is defaulted to 26 .
2. The unit will firstly run at high fan speed for 8s and then switch to preset fan speed.
3. When error of outdoor unit occurs or the unit stops for protection, indoor unit will keep its orignal operating state.
2.4 Heating Mode
1.Temp. can be set in the range of 16-30 .
4. Function of blowing residual heat:
2) When Tamb. , the unit runs under heating mode for cooling and heating type,Tpreset= .And it runs under fan
modes for cooling only type,Tpreset= .
3) When Tamb. , the unit keeps its original operating state. If first energization, it runs under fan mode.
2 0
2 5
2.6 Mode Conflict
If indoor room receives information from outdoor unit which is mode conflict, indoor unit will stop all loads( indoor fan,swing) after
buzzer gives out a beep.Running indicator falshes 7 times and other indicators keep normal.The mode sending to outdoor
If indoor room receives information from outdoor unit which is mode conflict after timer on reaches, indoor unit will stop all loads
( indoor fan,auxiliary heater) after buzzer gives out a beep.Running indicator falshes 7 times and other indicators keep
normal.The mode sending to outdoor unit is also the one received by remote controller.
Controller Function Manual and Operation Instruction
Receiving the information from outdoor unit that compressor is stopped,indoor fan switches to low fan speed for 10s and
5. Anti-cold air
then stop.
3. If compress under heating mode stops for error ,indoor fan will run by blowing residual heat.
1).Common anti-cold air:If Tamb. , and compressor runs for 5s or Ttube , indoor fan begins to run at low fan
After heating compressor begins to run,indoor fan runs according to the following conditions:
speed.After 3 min at low speed or Ttube
indoor fan runs at preset speed. If Tamb. ,and compressor runs for
90s and Ttube , indoor fan won't run.When Ttube , or compressor runs above 90s,indoor fan runs at low speed.
After 3 min at low speed or Ttube ,indoor fan runs at preset speed.
2).Anti-cold air after defrosting: When compressor runs for 90s and Ttube , indoor fan won't run.WhenTtube
,
or compressor runs above 90s,indoor fan runs at low speed.After 3 min at low speed or Ttube , indoor fan runs at
preset speed.
Once running,indoor fan won't stop.Once at preset fan speed, it won't forcibly return to low speed.
unit is also the one received by remote controller.