Disassembly Procedures

Disassembly Procedures for Indoor Unit 

Operating Procedures / Photos 

1.Disassemble Front Grill and Filter

Manually pull the clasp 1 of front grill downwards to

open the front grill.Loose the clasp 2 with pincers to

Fig.7-1

,7-2

 

remove the front grill.

2.Disassemble Left and Right Decorative Panels 

Unscrew the 2 screws on the left and right decorative 

panels and them push the panels upwards forciblely

to take them out.

Fig.7-

3,7-4

 

Grill Clasp 1

Front Grill

Fig.7-1

Fig.7-

2

Grill Clasp 2

Filter

Fig.7-

3

Screws

Floor Ceiling Series

Содержание ACP-12CFIFM35GEI

Страница 1: ...ACP 12CFIFM35GEI RoHS Service manual ENG ...

Страница 2: ......

Страница 3: ...ap m m 2 1 6 3 1 6 3 1 6 Coil length 1 height H coil width L 586 247 25 4 586 247 38 1 586 247 38 1 Swing Motor Model MP35CB P35CA MP35CB P35CA MP35CB P35CA Output of Swing Motor W 2 2 2 2 2 2 Fus e A Sound Pres s ure Level dB A H M L 45 40 32 46 43 36 54 50 47 Sound Power Level dB A H M L 55 50 42 56 53 46 64 60 57 Dim ens ion W H D m m Dim ens ion of Package L W H m m Net Weight Gros s Weight m ...

Страница 4: ...for ACP 12CFIFM35GEI C Co om mp po on ne en nt t N Na am me e C Co om mp po on ne en nt t N Na am me e Swing assy Air outlet Decorative panel Front grill Remote controller Air inlet Indoor Unit Floor Ceiling Series ...

Страница 5: ...4 0 6 2 745 836 238 695 Outline and Installation Dimension Outline and Installation Dimension of Indoor Unit Outline Dimension Installation Dimension ...

Страница 6: ...5 ACP 12CFIFM35GEI Electric Diagram Floor Ceiling Series ...

Страница 7: ...ode Conflict If indoor room receives information from outdoor unit which is mode conflict indoor unit will stop all loads indoor fan swing after buzzer gives out a beep Running indicator falshes 7 times and other indicators keep normal The mode sending to outdoor If indoor room receives information from outdoor unit which is mode conflict after timer on reaches indoor unit will stop all loads indo...

Страница 8: ...id button or remote controller the buzzer will give out a beep Stepping motor is controlled for startup and stop by swing button It s swing is valid only when indoor fan is running 3 3 Swing Control As the right figure Fig 2 A is close position B is min position and C is max position The angle between A and B is 64 degrees and betwwen B and C is 60 degrees 1 Power the unit on for reset Swing motor...

Страница 9: ...indicator flashes for once 2 Indicators of indoor light board Under normal operation red indicator running indicator yellow indicator heating indicator and green indicator cooling indicaor 3 After re energization the unit will run under the state befor power failure TIMER It should be reset 0HDQLQJ UHG HOORZ JUHHQ RPSUHVVRU KLJK SUHVVXUH SURWHFWLRQ XQLW VWRS OLQN RQFH QGRRU XQLW DQWL IUHH LQJ SURW...

Страница 10: ... state display 13 Button for temp decrease 5 Set temp display 14 FAN button 6 Ambient temp display 15 SWING button 7 Fresh air display 16 TIME button 8 Mode COOL DRY FAN HEAT AUTO 17 ON OFF button 9 Malfunction display 18 Display of Swing state Floor Ceiling Series 3 10 Turbo Function invalid when connected with wire controller After setting of turbo function by remotr controller indoor fan will r...

Страница 11: ...it stop System Unit malfunction IPM modular protection unit stop PFC protection unit stop Compressor malfunction Indoor pipe temp sensor malfunction Outdoor ambient temp sensor malfunction Outdoor pipe temp sensor malfunction Outdoor air exhaust temp sensor malfunction E2 PROM Error Wire controller ambient temp sensor malfunction 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 E1 E2 E3 E4...

Страница 12: ...ownwards to open the front grill Loose the clasp 2 with pincers to Fig 7 1 7 2 remove the front grill 2 Disassemble Left and Right Decorative Panels Unscrew the 2 screws on the left and right decorative panels and them push the panels upwards forciblely to take them out Fig 7 3 7 4 Grill Clasp 1 Front Grill Fig 7 1 Fig 7 2 Grill Clasp 2 Filter Fig 7 3 Screws Floor Ceiling Series ...

Страница 13: ...e it Fig 7 5 Fig 7 5 4 Disassemble Rear Side Plate air outlet Remove the flanneletteand unscrew the 2 screws at the rear side plate to remove it Fig 7 6 Fig 7 6 5 Disassemble Guide Louver Top the middle of guide louver and pull it out from the middle clasp and then bend the right and left axile bushes to take the Fig 7 7 guide louver out Fig 7 7 7 8 Operating Procedures Photos ...

Страница 14: ...ssemble Evaporator Assy Unscrew the 4 screws fixing the cover plate of evaporator Pull out the 3 temp sensors on the Fig 7 10 7 11 7 12 pipes and then unscrew the 2 screws at the left side of evaporator to remove it by inclined lift Fig 7 10 Screws Screws Evaporator Cover Plate Fig 7 8 Axile Bush Operating Procedures Photos Floor Ceiling Series ...

Страница 15: ...electric box cover to pull out the cover upwards Loosen the wiring Fig 7 13 7 14 terminals of fan motor and guide louver motor and then remove the ambient temp sensor bound by the tie line at the side of elelctric box At last unscrew the 3 screws fixing the electric box to remove it Screws Fig 7 13 Fig 7 14 Ambient Temp Sensor Screws ...

Страница 16: ...crew the 1 screw fixing cross flow fan with a inner hexagon spanner to remove it Fig 7 15 7 16 Clasps Fig 7 15 Fig 7 16 Cross Flow Fan Screw 10 Disassemble Motor Loosen the 4 nuts fixing the support to remove the motor sub assy and then unscrew the 2 bolts onthe clamping band to remove the motor Fig 7 17 Fig 7 17 Nuts Clamping Band Bolts Floor Ceiling Series ...

Страница 17: ...8 E Ex xp pl lo od de ed d V Vi ie ew w a an nd d C Co om mp po on ne en nt ts s a an nd d P Pa ar rt ts s L Li is st t Exploded View ...

Страница 18: ...vaporator 1 1 4 2 7 0 1 0 1 1 4 2 7 0 1 0 1 16 Foam of Right Side Plate 4 0 4 2 1 3 2 1 4 0 4 2 1 3 2 1 1 17 Right Fixing Plate 4 0 4 2 3 3 1 0 4 0 4 2 3 3 1 0 1 18 Right Decoration Panel 7 2 0 2 1 1 6 2 7 2 0 2 1 1 6 2 1 19 Pipe Clamp Plate 1 0 7 3 4 2 7 0 1 0 1 0 7 3 4 2 7 0 1 0 1 20 Capacitor CBB611A 1uF 500V 0 2 0 0 1 0 3 3 9 8 0 0 1 0 3 3 1 21 Transformer 3 1 0 0 1 1 3 4 3 1 0 0 1 1 3 4 1 22 ...

Страница 19: ... 6 4 2 2 2 3 0 1 Air Collecting Pipe Components 5 2 4 3 3 5 3 0 0 0 2 3 3 5 3 0 1 Temp Sensor 15K 6 8 1 0 0 0 9 3 6 8 1 0 0 0 9 3 1 Temp Sensor 20K 3900019817 3900019817 1 Temp Sensor 20K 3900019818 3900019818 1 Temp Sensor 20K 3900019819 3900019819 1 50 Temp Sensor Insert 3 6 0 0 2 0 2 4 3 6 0 0 2 0 2 4 3 51 Water Lead Panel 1 0 0 2 6 3 1 0 1 0 0 2 6 3 1 0 1 52 Cover of Evaporator 9 0 4 2 7 0 1 0...

Страница 20: ...22 Electric Box 1 23 Main PCB M901F2AJ 1 24 Terminal Board RS9413 1 Wire Clamp 1 Insulate mat slice 1 26 Fuse 5A 250VAC 27 Cover of Electric Box 1 28 Pipe Clip 1 29 Drainage Pipe 1 30 Display Board 5T52 1 31 Electric Box 1 32 Front Grill Clip 1 2 33 Filter 1 34 Front Grill 1 No Description Qty 25 01302013 26232001 261124151 01302015 1051953201 261124161 10512026 24212019 10512025 24212018 10512027...

Страница 21: ...nsert 3 51 Water Lead Panel 1 52 Cover of Evaporator 1 53 Fixed Mount 1 54 Centrifugal Fan 2 55 Rear Snail Shell 2 56 Front Snail Shell 2 57 Axes Connector 1 58 Bar Clasp 4 59 Hoop 1 60 Motor PG40F 1 61 Remote Controller 1 62 Connecting Cable 1 63 Connecting Cable 1 1 No Description Qty Part Code GTHD 18 AANK3A1AI 201620041 01532001 01272205P 01709532 26112028 01332405 12312403 01072410 26112026 4...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Отзывы: