6.3 Pipe length and the elevation
The pipe length and refrigerant amount:
Model
Pipe size
Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
Gas
Liquid
3/8’’
(Ф9.52)
1/4’’
(Ф6.35)
5
8
20
20
5
8
20
20
1/2
’’
(Ф
12.7)
1/4’’
(Ф6.35)
5
10
25
20
5
/8’’
(Ф15.9)
3/8’’
(Ф9.52)
5
10
25
40
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the
system reliability.
The oil trap should be installed per 5-7 meters.
ACP-09CH25AELI
ACP-12CH35AELI
ACP-18CH50AELI
ACP-22CH65AELI