OPERATING INSTRUCTIONS
Range
Adjust the air flow direction properly, otherwise it
might cause discomfort or cause uneven room
temperatures.
Adjust the horizontal louver using the remote
controller.
Adjust the vertical louver manually.
To set the vertical air flow(Up--Down) direction
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow
direction. The horizontal louver can be moved at
a range of 6
O
for each press, or swing up and down
automatically. Please refer to the
,,
REMOTE
,,
CONTROLLER OPERATION MANUAL for details.
To set the horizontal air flow direction (left - right)
Move the deflector rod manually to adjust the air flow
in the direction you prefer.
IMPORTANT
:Do not put your fingers into the panel of
blower and suction side.The high-speed fan inside may
cause danger.
CAUTION
7
8
Do not operate the air conditioner for long periods with the
air flow direction set downward in cooling or dehumidifying
mode. Otherwise, condensation may occur on the surface
of the horizontal louver causing moisture to drop on to the
floor or on furnishings.
When the air conditioner is started immediately after it was
stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set too
small, as COOLING or HEATING performance may be
impaired due to too restricted air flow area.
Do not move the horizontal louver manually, otherwise the
horizontal louver will be out of sync. Please cease
operating, unplug power for a few seconds,then restart the
air conditioner.
Do not operate unit when the horizontal louver is in closed
position.
Range
Deflecto
r rod
OPERATING INSTRUCTIONS
NOTE: This manual does not include Remote Controller Operations, see the
<<Remote Controller Instruction>> packed with the unit for details.
Operating temperature
NOTE:
1. Optimum performance will be achieved within these operating temperatures.If air
conditioner is used outside of the above conditions, certain safety protection features might
come into operation and cause the unit to function abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over 80%) ,
condensed water may drip out of the unit. Please sets the vertical air flow louver to
its maximum angle (vertically to the floor), and set HIGH fan mode.
Suggestion:
For the unit adopts an Electric Heater, when the outside ambient temperature
is
below 0
O
C(32
O
F), we strongly recommend you to keep the machine plugged in order to
guarantee it running smoothly.
Manual operation
Units are equipped with a switch to run emergency operation mode. It can be accessed by
opening the front panel. This switch is used for manual operation in case the remote controller
fails to work or maintenance necessary.
AUTO/COOL
Manual switch
NOTE:
The unit must be turned off before
operating the manual control button. If the
unit is operational, continue pressing the
manual control button until the unit is off.
1 Open and lift the front panel up to an angle
until it remains fixed with a clicking sound.
2 One press of the manual control switch will
lead to the forced AUTO operation. If press
the switch twice within five seconds, the unit
will operate under forced COOL operation.
3 Close the panel firmly to its original position.
CAUTION:
●
This switch is used for testing purposes
only. You had better not choose it.
●
To restore the remote controller operation,
use the remote controller directly.
7
8
Mode
Temperature
Cooling operation
Cooling operation
Drying operation
Room temperature
17
O
C~32
O
C
(62
O
F~90
O
F)
0
O
C~30
O
C
(32
O
F~86
O
F)
10
O
C~32
O
C
(50
O
F~90
O
F)
Outdoor temperature
-15
O
C~50
O
C
(5
O
F~122
O
F)
(For the models with low
temperature cooling system)
-15
O
C~30
O
C
(5
O
F~86
O
F)
0
O
C~50
O
C
(32
O
F~122
O
F)
NOTE:
1. Optimum performance will be achieved within these operating temperatures.If air conditioner is used outside of
the above conditions, certain safety protection features might come into operation and cause the unit to function
abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over 80%) , condensed water may
drip out of the unit. Please sets the vertical air flow louver to
its maximum angle (vertically to the floor), and set HIGH fan mode.
Suggestion:
For the unit adopts an Electric Heater, when the outside ambient temperature
is below 0
O
C(32
O
F), we
strongly recommend you to keep the machine plugged in order to guarantee it running smoothly.
Содержание ACP-09CH25AEFI
Страница 2: ......
Страница 3: ...HR BIH CG Upute za uporabu ACP 09CH25AEFI ACP 12CH35AEFI ACP 18CH50AEFI Klima uređaj ...
Страница 27: ...SR BIH CG Korisničko uputstvo Klima uređaj ACP 09CH25AEFI ACP 12CH35AEFI ACP 18CH50AEFI ...
Страница 50: ......
Страница 51: ...MAK Упатство за употреба Kлиматизација ACP 09CH25AEFI ACP 12CH35AEFI ACP 18CH50AEFI ...
Страница 74: ......
Страница 75: ...AL Udhëzime për shfrytëzim Ajër i kondicionuar ACP 09CH25AEFI ACP 12CH35AEFI ACP 18CH50AEFI ...
Страница 98: ......
Страница 99: ...PL Instrukcja obsługi Klimatyzacja ACP 09CH25AEFI ACP 12CH35AEFI ACP 18CH50AEFI ...
Страница 121: ...SLO Navodila za uporabo Klima ACP 09CH25AEFI ACP 12CH35AEFI ACP 18CH50AEFI ...
Страница 144: ......
Страница 145: ...SK Návod na použitie Klimatizácia ACP 09CH25AEFI ACP 12CH35AEFI ACP 18CH50AEFI ...
Страница 168: ......
Страница 169: ...EN User manual Air conditioner ACP 09CH25AEFI ACP 12CH35AEFI ACP 18CH50AEFI ...
Страница 204: ...3 4 Kim Tec servis d o o Poslovni centar 96 2 72250 Vitez Tel 030 718 844 FAX 033 755 996 e mail servis kimtec ba ...
Страница 211: ...3 4 3 4 3 4 ...
Страница 220: ...www VIVAX com ...