Operating Instructions

Appliance description

Operating modes

Exhaust-air mode:

The extractor-hood fan extracts the
kitchen vapours and conveys them
through the grease filter into the
atmosphere.

The grease filter absorbs the solid
particles in the kitchen vapours.

The kitchen is kept almost free of grease
and odours.

 

When the extractor hood is operated in

exhaust-air mode simultaneously with a
different burner which also makes use of

 the

same chimney 

(such as gas, oil or coal-fired

heaters, continuous-flow heaters, hot-water
boilers) care must be taken to ensure that
there is an adequate supply of

 fresh air

which will be needed by the burner for
combustion.

Safe operation is possible provided that the
underpressure in the room where the burner
is installed does not exceed 4 Pa (0.04
mbar).

Operating modes

This can be achieved if combustion air can
flow through non-lockable openings, e.g.
indoors, windows and via the air intake/
exhaust-air wall box or by other technical
measures, such as reciprocal interlocking,
etc.

If the air intake is inadequate, there is a
risk of poisoning from combustion gases
which are drawn back into the room.

An air-intake/exhaust-air wall box by itself is
no guarantee that the limiting value will not
be exceeded.

Note:

 When assessing the overall

requirement, the combined ventilation
system for the entire household must be
taken into consideration.

This rule does not apply to the use of
cooking appliances, such as hobs and
ovens.

Unrestricted operation is possible if the
extractor hood is used in recirculating mode–
with activated carbon filter.

Circulating-air mode:

An activated carbon filter must be fitted
for this operating mode (see Filters and
maintenance).

The complete installation set and

replacement filters can be obtained 

from

specialist 

outlets.

The extractor-hood fan extracts the
kitchen vapours which are purified in the
grease filter and activated carbon filter
and then conveyed back into the kitchen.

The grease filter absorbs the grease
particles in the kitchen vapours.

The activated carbon filter binds the
odorous substances.

If no activated carbon filter is

installed, it is not possible to bind the
odorous substances in the cooking
vapours.

Light / fan

switches

Filter grille

Lighting

Содержание VVA62U150

Страница 1: ...1 EN Instruction for mounting and use FR Prescriptions de montage et mode d emploi...

Страница 2: ...2 en page 3 13 fr page 14 24 599 60 510 132 125 410 85...

Страница 3: ...tc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting...

Страница 4: ...should be monitored to ensure that they do not play with the appliance The hood must NEVER be used as a support surface unless specifically indicated If the connecting cable for this appliance is dama...

Страница 5: ...iciency of the extractor hood can also be adversely affected Important By cleaning the metal grease filters at appropriate intervals the possibility of them catching fire as a result of a build up of...

Страница 6: ...ore saturated with grease there is an increased risk of fire and the function of the extractor hood may be impaired Important Change the activated carbon filter promptly to prevent the risk of fire fr...

Страница 7: ...inless steel cleaner Clean the surface in the same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents conta...

Страница 8: ...e contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal...

Страница 9: ...doors windows and in conjunction with an air supply air intake wall box or by other technical procedures such as reciprocal interlocking This can be achieved if the combustion air is able to flow thr...

Страница 10: ...there will be an increase in noise Round pipes Short discharge pipe Inner diameter at least 100 mm extended discharge pipe Inner diameter at least 125 mm Flat ducts must have an inner crosssection equ...

Страница 11: ...rovided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area If it not fitted with a plug direct mains connection or if the plug is not...

Страница 12: ...od 6 Tighten the lower screw with washer inside the extractor hood Fitting the extractor hood To a wall hanging cupboard With 4 screws 1 Dimensions for the mounting boreholes can be found in or place...

Страница 13: ...13 Final assembly Selecting the operating mode Exhaust air mode Position A Circulating air mode Position F A F A F Connect to the power supply...

Страница 14: ...est implant ne d passe pas 4 Pascals 0 04 mbars Modes de fonctionnement On y parvient en pr sence d ouvertures non obturables m nag es par ex dans les portes fen tres et en association avec des ventou...

Страница 15: ...uchant la surface du corps de la hotte ou d endommager carr ment cette Remarques importantes La pr sente notice d emploi vaut pour plusieurs versions de l appareil Elle peut contenir des descriptions...

Страница 16: ...e Attention Plus elles se saturent en particules grasses et plus elles risquent de s enflammer D autre part leur saturation risque de g ner le bon fonctionnement de la hotte Important Pr venez tout ri...

Страница 17: ...Attention Plus elles se saturent en particules grasses et plus elles risquent de s enflammer D autre part leur saturation risque de g ner le bon fonctionnement de la hotte Filtre et entretien Importa...

Страница 18: ...ier inox dans le sens de son polissage Ne nettoyez jamais les surfaces en acier inox avec des ponges dos r curant et pas non plus avec des d tergents base de sable soude caustique acide ou chlore Surf...

Страница 19: ...espectant l environnement Demandez votre revendeur ou votre mairie quelles sont les formes de recyclage actuellement possibles Cette hotte peut vacuer l air l ext rieur ou le recycler Fixez toujours l...

Страница 20: ...ou au charbon chauffe eau instantan s ou accumulation raccord s une chemin e veiller imp rativement ce que l apport d air soit suffisant pour assurer la marche du chauffage combustion Un fonctionnemen...

Страница 21: ...fort diam tre 125 mm de pr f rence et que les coudes soient les plus arrondis possibles L emploi de conduits d air vici longs rugueux formant de nombreux coudes ou d un trop petit diam tre fait descen...

Страница 22: ...murale conforme aux normes en vigueur et plac e dans une zone accessible Si aucune prise n est pr sente raccordement direct au circuit lectrique ou si la prise ne se trouve pas dans une zone accessibl...

Страница 23: ...int rieur de la hotte vissez la vis inf rieure quip e de sa rondelle intercalaire Fixation sous un placard en appui mural Par 4 vis 1 Reportez sur la paroi inf rieure du placard les cotes d cartement...

Страница 24: ...24 Finition du montage R glage du mode Mode Air vacu position A Mode Air recycl position F A F A F Effectuez le branchement lectrique...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...Subject to modification Tous de modification r serv s BSH Hausger te Vertriebs GmbH Carl Wery str 34 81739 M nchen Germany LI3DPA Ed 10 07...

Отзывы: