background image

Warranty 

Warranty 

The 

Vitrek

 instrument is warranted against defects in material and workmanship 

for a period of one year after the date of purchase.  

Vitrek

 agrees to repair or 

replace any assembly or component (except batteries) found to be defective, 
under normal use, during the warranty period.  

Vitrek's

 obligation under this 

warranty is limited solely to repairing any such instrument, which in 

Vitrek's

 

sole opinion proves to be defective within the scope of the warranty, when 
returned to the factory or to an authorized service center.  Transportation to the 
factory or service center is to be prepaid by the purchaser. Shipment should not 
be made without prior authorization by 

Vitrek

.   

The warranty does not apply to any products repaired or altered by persons not 
authorized by 

Vitrek

, or not in accordance with instructions provided by 

Vitrek

.  

If the instrument is defective as a result of misuse, improper repair, or abnormal 
conditions or operations, repairs will be billed at cost. 

Vitrek

 assumes no responsibility for its product being used in a hazardous or 

dangerous manner, either alone or in conjunction with other equipment.  Special 
disclaimers apply to this instrument. 

Vitrek

 assumes no liability for secondary 

charges or consequential damages, and, in any event, 

Vitrek's

 liability for breach 

of warranty under any contract or otherwise, shall not exceed the original 
purchase price of the specific instrument shipped and against which a claim is 
made. 

Any recommendations made by 

Vitrek

 or its Representatives, for use of its 

products are based upon tests believed to be reliable, but 

Vitrek

 makes no 

warranties of the results to be obtained.  This warranty is in lieu of all other 
warranties, expressed or implied, and no representative or person is authorized 
to represent or assume for 

Vitrek

 any liability in connection with the sale of 

Vitrek

 products other than set forth herein. 

Instrument Serial Number: __________________________________ 

Содержание XiTRON XT560

Страница 1: ...USER GUIDE XT560 Digital Milliohmmeter...

Страница 2: ...2 XT560 Digital Milliohmmeter User Guide...

Страница 3: ...tive as a result of misuse improper repair or abnormal conditions or operations repairs will be billed at cost Vitrek assumes no responsibility for its product being used in a hazardous or dangerous m...

Страница 4: ...ation which is subject to change without notice The product s displays and manual text may be used or copied only in accordance with the terms of the license agreement is a trademark of Vitrek All oth...

Страница 5: ...__________________ 14 Range Selection_____________________________________________ 14 HOLD Mode ________________________________________________ 15 Four Wire Measurement ______________________________...

Страница 6: ...ntents Dimensions ________________________________________________ 23 APPENDIX B MEASUREMENT SPECIFICATIONS _______________________ 24 Specification ___________________________________________________...

Страница 7: ..._______________________________ 14 Figure 5 Standing Position ________________________________________ 14 Figure 6 Stand as a Handle _______________________________________ 14 Figure 7 Changing Positi...

Страница 8: ...fixed range The XT560 includes a set of Kelvin test clip leads for making four terminal measurements The XT560 is ideal for measuring wiring or cable resistances windings of motors or generators lamp...

Страница 9: ...Introduction 9 High Accuracy 0 05 Auto Manual Function RS 232 Interface Standard Measurement Speed 10 samples sec HOLD REL Function...

Страница 10: ...on This chapter describes the operation and interfaces of the XT560 Digital Milliohmmeter Front Panel The front panel of the XT560 is shown in Figure 1 below FRONT PANEL DIAGRAM Figure 1 Front Panel X...

Страница 11: ...601 digital ohm meter is a 6 digit 0 56 numerical LED display The following characters indicate the unit of the value displayed M Mega 1 106 ADDR Address K Kilo 1 103 REL Relative m Milli 1 10 3 CAL C...

Страница 12: ...ar Panel Refer to Figure 2 1 RS 232 Connector 2 Power Line Cord Connector AC 90 264V 50 60Hz 3 Fuse for power 250V 1A 4 Fuse for input 250V 0 5A Figure 2 Rear Panel Replacement fuses must be the same...

Страница 13: ...Figure 3 Meter Dimensions Stand Operation There are 3 positions for the XT560 stand Figures 4 5 and 6 illustrate the XT560 with the stand fully retracted horizontally as a stand and as a handle Figure...

Страница 14: ...igure 7 Changing Positions Using the Meter Range Selection The XT560 digital milliohmmeter has two ranging modes Manual and Auto The measurement range can be selected using either auto range by pressi...

Страница 15: ...HOLD Mode When the XT560 is operating in the display hold mode pressing the HOLD key allows the user to take a measurement and hold that measurement value on the display Press the HOLD key again to re...

Страница 16: ...riod of time as specified in Reference Table 1 Then press the SHIFT and TRIG keys at the same time 4 Connect the Resistor Standard to the meter in a 4 wire configuration refer to Figure 9 Wait for a p...

Страница 17: ...LD 1 30 0 3 sec SHIFT TRIG SHIFT HOLD 10 300 0 3 sec SHIFT TRIG SHIFT HOLD 100 3K 0 3 sec SHIFT TRIG SHIFT HOLD 1k 30K 0 3 sec SHIFT TRIG SHIFT HOLD 10k 300K 0 3 sec SHIFT TRIG SHIFT HOLD 100k 3M 0 5...

Страница 18: ...18 Calibration Figure 9 Calibration with Resistor Standard...

Страница 19: ...he RS 232 interface can only be performed from the front panel To change the baud rate perform the following Press and hold the SHIFT key then press the REL to display the present communication rate A...

Страница 20: ...Sub Command1_Click send command to XT560 MSComm1 Output VAL Chr 13 delay 1 second to read XT560 Timer1 Enabled True End Sub Private Sub Form_Load set serial port MSComm1 InputMode comInputModeText MS...

Страница 21: ...n the lamp is on HOLDCLR Meter exits HOLD mode and display returns to normal operation REL Meter reads resistance as a relative value In REL operation auto range is disabled RELCLR Meter exits the rel...

Страница 22: ...22 Local and Remote Operation RANGE Sets the display to the range from 1 to 9 as shown in the table below Range Value Ohms range 1 300m 2 3 3 30 4 300 5 3k 6 30k 7 300k 8 3M 9 30M...

Страница 23: ...Specifications subject to change without notice Environment Operating 0 C to 50 C 80 RH non condensing Storage 20 C to 70 C non condensing Altitude Equivalent Atmospheric pressures and air densities...

Страница 24: ...r Supply AC 90 264V 50 60Hz 15VA RS 232 Baud rates 300 2400 9600 No parity one Stop bit Range Test Range Resolution Test Current Accuracy 300 00m 0 01m 330 00m 10 DC 100mA 0 05 20digits 3 0000 0 0001...

Отзывы: