2.3  Power supply

The 24 V distributor enables power supply to a maximum 

of 8 connections, each with a maximum of 2 converters of 

75 W. The switched input enables the use of a switch.

NV (24 V)

L = 500 mm

120–240 V

L = 200 mm

ø 7.7 mm

Fig. 3:  Converter

NoTe! It is imperative to take account of power 

consumption of the electrical devices. 

The dimmer set 318-271.19 is required for the use of 

dimmers.

For an overview of the electrical connection of the frames 

and the associated components see the section on Elec­

trification 3.11.

2.4  Scope of supply and accessories

2.4.1 merchandise supports/shelves

Shelves are trays or racks made of wood or glass.  

They act as supports for the goods and are inserted  

in the frames.
In addition, non­electrified merchandise supports from 

the Xero Frame P/L range can be used.
Further information on the individual merchandise sup­

ports as well as the specific product descriptions can be 

found in the product catalogue. 

2.4.2 Single power adapter 24 V

A

B

Fig. 4:  Single power adapter 24 V

Adapters are used for power transfer from the profile  

to the merchandise support/electrical device.
The adapters may only be used with profiles from the 

Xero Frame P/L, Xero L P/L and Xero Twin P/L range.
Low voltage lamps and low voltage small electrical  

devices must only be connected by an electrician.
The number of adapters and electrical devices must  

be such that the combined load does not exceed  

the nominal current rating or fuse protection. The permit­

ted nominal voltage and current of the adapters  

are also correspondingly restricted (see labelling and 

safety instructions). 
Permitted nominal current max. 4 A

2.5  Product safety

Details of the electrified Xero Frame P/L: Power track 

with power supply integrated into the system sup­

port profile.
Safety and functionality is guaranteed with proper inten­

ded use. Any liability relating to improper use will  

be refused. Product safety is exclusively related to the 

Xero Frame P/L original accessories from Vitra. 

Modifications must not be made to the system for  

safety reasons. 

The safety instructions in the assembly instructions must 

be observed as well as notices on component labels. The 

nominal current rating (A) shown must not be exceeded. 

With improper use or cleaning with fluids, parts that are 

touched can be live. 

Tracks and adapters with visible damage must be dis­

connected from the power supply. An electrician must be 

notified immediately.

 

NOTE

Use only Xero Frame P/L system accessories!  

Do not use any third party components

It is the responsibility of the user to ensure the electrical, 

mechanical and thermal compatibility between the po­
wer track system and the attached electrical devices.

Содержание Xero Frame L

Страница 1: ...Xero Frame P L ASSEMBLY AND OPERATING INSTRUCTIONS...

Страница 2: ...ro Frame P L product These instructions are part of the product and must be kept safely and in easy reach from the product at all times All persons who use or handle this product must have read these...

Страница 3: ...onnel visual merchandisers Misuse WARNING In the event of misuse there is the danger that the merchandise supports and the electrical devices will be damaged This may lead to injury and da mage to the...

Страница 4: ...voltage lamps and low voltage small electrical devices must only be connected by an electrician The number of adapters and electrical devices must be such that the combined load does not exceed the no...

Страница 5: ...1 2 3 4 5 5 Xero Frame P L v 1 2018 EN 1 2018 EN EN 2 6 Overview of wall units 1 Xero Frame P L frame 2 Glide 50 mm 3 Wall bracket set for frame 4 Frame connection with wall bracket 5 Frame connection...

Страница 6: ...ero Frame P L v 1 2018 EN EN 2 7 Overview of central space 6 Flat panel base for gondola 7 H frame base for gondola 8 Back panel clip set for wooden back panels 9 Interchangeable frame for printed tex...

Страница 7: ...ansport company Initiate a complaint Packaging The product is securely packed so that transport damage is unlikely Store original packaging for subsequent transport Only send product in original packa...

Страница 8: ...Frame P L v 1 2018 EN EN 3 5 Connecting cable set 3 7 Assembling frame connection 3 7 1 Set of wall mounting brackets 1 Aligning frame 2 Fixing the frame with the frame connections to the wall 3 6 Mo...

Страница 9: ...30 46 76 9 Xero Frame P L v 1 2018 EN 1 2018 EN EN 3 7 2 Frame connection with wall fixing bracket 1 Aligning frame 2 Fixing the frame with the frame connections to the wall 3 8 Frame connection grips...

Страница 10: ...SW6 10 Xero Frame P L v 1 2018 EN EN 3 9 Mounting gondola bases 3 10 Mounting interchangeable frame...

Страница 11: ...erter Operation with 150 W converter 3 11 Vitra plug system NOTE It is imperative to take account of power con sumption of the electrical devices The maximum power consumption should be 10 below the n...

Страница 12: ...ng Have electrical and electronic components disposed of by an approved waste management specialist Dispose of remaining components sorted according to the type of material 6 Technical data 6 1 Dimens...

Страница 13: ...ation Value Unit Nominal voltage 24 V Nominal current rating maximum 4 A 6 3 Load values The maximum load applies including the dead weight and the weight of all components Frame Specification Value U...

Страница 14: ...www vitra com retail vitra com...