Installation Instructions
1. Remove the dust protection cap from the lens mount.
2. Screw the lens onto the camera firmly (do not over tighten).
3. Plug the lens into the lens connector on the rear of camera case.
4. Mount the camera to the wall or ceilling with a corresponding mounting bracket
through the camera mount holes (1/4” thread insert) on its top or bottom.
CAUTION
Installation and commissioning Instructions
• Make sure the power is removed before installation.
• Follow the order for applying power.
When using 12VDC or 24VAC power make power connections
at camera first then apply power. this will help avoid unnecessary
power surges to camera.
• Care should be taken the cable is NOT damaged, kinked or exposed in
any hazardous area.
• Do not expose the camera lens directly to a strong light source such as the sun or
spot light.
Setting the back focus adjustment
For easier and better adjustment, this camera provides FOCUS ADJUST menu
which will assist you in the focusing of the camera.
When enabling FOCUS ASSIST menu, follow the procedure to get the best back
focus adjustment.
1. Set the lens for the zoom position to WIDE and the focus position to INFINITE(∞).
2. Point the camera at an object about 30' away
3. Adjust ’Back focus adjusting Flange’ until the optimum focus is achieved.
4. Set the lens zoom position to TELE and adjust the lens focus for best focus.
5. Set the lens zoom position to WIDE again, check if the focus adjustment
was the best. If not, re-adjust ‘Back focus Flange’ slightly.
6. After the setting, tighten the ‘Flange lock screw’ with L-wrench supplied.
Start up
When the camera is powered properly, it starts up with initializing the internal
parameters.
FULL-HD MEGA-PIXEL CAMERA
08