VT-PTZ12WH
29
3.2
ALARM
( MENU => ALARM)
Highlight
ALARM
in the main menu and move the joystick to the right to access
ALARM
setup.
NO : Alarm input number
FUNC : Priority 1~4 calls Preset(xxx),
Priority 0 supports dedicated functions like a Pattern(Pxx), Tour(Txx),
Scan(Sxx).
PRI : Lower No. has higher priority, Equal priority alarms will be serviced
repeatedly.
IN
: NO/NC - normally open /Closed, OFF - ignore
OUT : R01 - Relay out 1, OFF - No output.
HLD : Alarm will be held for programmed time (01 to 99 seconds)
LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated
alarms only.
There are 5 levels of priority. 0 : Highest priority supports repeated/dedicated
functions like a Pattern(Pxx), Tour(Txx), Scan(Sxx). 1~4: Same level of alarm
calls presets one after the other.
Ex) Alarm 01 calls Pattern 01, after alarm 01 is released alarm 02, 03 will call
preset 48
and
preset 01
MAIN MENU
FUNCTIONS
ALARM
SCREEN
CAMERA
SETUP
EXIT
ALARM SETUP
NO FUNC PRI IN OUT HLD LATCH
01
P
01 0 OFF OFF 001 OFF
02 048 3 OFF OFF 001 OFF
03 001 1 OFF OFF 001 OFF
04 --- 3 OFF OFF 001 OFF
SAVE AND EXIT
Содержание VT-PTZ12WH
Страница 4: ...VT PTZ12WH 3 WARNING AND CAUTION...
Страница 12: ...VT PTZ12WH 11 2 5 Connecting Both Speed Dome and DVR via J box Figure 5 Connecting Camera DVR into Controller...
Страница 15: ...VT PTZ12WH 14...
Страница 48: ...28492 Constellation Road Valencia ca 91355 WWW VITEKCCTV COM Version 1 12 2014...